1  Intended use 

Precise measurements of conductivity in pure water applications  

Applications 

 

  Fresh and seawater aquaristics 

  Fish farming 

  Drinking water monitoring 

etc. 

2  General advice 

Read through this document attentively and make yourself familiar to the operation of the device 
before you use it. Keep this document in a ready-to-hand way in order to be able to look up in 
the case of doubt. 

3  Safety instructions 

This device has been designed and tested in accordance to the safety regulations for electronic 
devices. 
However, its trouble-free operation and reliability cannot be guaranteed unless the standard 
safety measures and special safety advises given in this manual will be adhered to when using 
it. 

1.  Trouble-free operation and reliability of the device can only be guaranteed if it is not 

subjected to any other climatic conditions than those stated under “Specification”.  

2.  Transporting the device from a cold to a warm environment condensation may result in a failure 

of the function. In such a case make sure the device temperature has adjusted to the ambient 
temperature before trying a new start-up. 

3.  The circuitry has to be designed most carefully if the device should be connected to other 

devices. Internal connection in third party devices (e.g. connection GND and earth) may 
result in not-permissible voltages impairing or destroying the device or another device 
connected.  

4.  Whenever there may be a risk whatsoever involved in running it, the device has to be 

switched off immediately and to be marked accordingly to avoid re-starting. Operator safety 
may be a risk if: 
- there is visible damage to the device or the device is not working as specified 
- the device has been stored under unsuitable conditions for a longer time 
In case of doubt, please return device to manufacturer for repair or maintenance. 

5. 

Warning: 

Do not use this product as safety or emergency stop device, or in any other 

application where failure of the product could result in personal injury or material damage. 
Failure to comply with these instructions could result in death or serious injury and material 
damage. 

4  Operation and Maintenance 

  If the symbol 

"

BAT” 

is displayed at the left side of display, the battery is weak, measuring can 

be continued for a short period. If 

“bAt”

 is displayed in the main display the battery is used up 

and needs to be replaced. Measuring is no more possible. 

  The battery has to be removed, when storing device above 50 °C. 

Hint:  We recommend removing the battery if device is not used for a longer period of 

time! Risk of Leakage  

  Treat device and probes carefully. Use only in accordance with above specification. 

(do not throw, hit against etc.). Protect from soiling. 

 

After switching on the instrument a segment test (all segments) is displayed, followed by 
“P.off”, 
if auto power off function is activated (please refer to configuration) 
 

 

Summary of Contents for GLF 100 RW

Page 1: ...chnik GmbH Standort Greisinger Hans Sachs Str 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de WEEE Reg Nr DE 93889386 Conductivity Measuring Instrument as of version 1 2 Op...

Page 2: ...shbuttons 4 7 1 Min max value memory 4 7 2 Hold function 4 8 Configuration oft he instrument 5 9 Adjusting oft the instrument 6 10 System Messages 6 11 Inspection of the accuracy Adjustment Services 6...

Page 3: ...result in not permissible voltages impairing or destroying the device or another device connected 4 Whenever there may be a risk whatsoever involved in running it the device has to be switched off im...

Page 4: ...reset Min and Max value hold Hold current measuring value HLD in display 7 1 Min max value memory The lowest and highest measured value since the turning on of the device will be stored The stored va...

Page 5: ...easuring of TDS 0 2000 mg l 50 0 SAL Measuring of Salinity 0 0 50 0 g kg Unit of temperature display factory setting C C temperature is displayed in C factory setting F temperature is displayed in F T...

Page 6: ...setting of temperature measurement see below Scale correction of temperature 5 00 5 00 Scale adjustment of temperature measurement Display measured value offset 1 scale adjustment 100 Pressing again s...

Page 7: ...f the instrument is very constant if it is used as intended Depending on the necessary accuracy the instruments can be used up to several years without recalibration of the cell constant If the accura...

Page 8: ...instrument 25 50 C Temperature cell 5 80 C short time 100 C Relative humidity instrument 0 95 RH non condensing Storage temperature 5 50 C Housing Dimension 110 x 67 x 30 mm H x W x D impact resistant...

Reviews: