G 1690 / G 1690T
Operation | 4
B-H86.0.31.DK2-1.0
11 / 20
L,TE
Backlight
OFF
Backlight deactivated
0:15
,
0:30
,
1:00
,
2:00
,
4:00
Automatic shut-off of the backlight after a selected
time in minutes:seconds, during which no buttons
have been pressed
ON
No automatic shut off of the backlight
IN,T
Factory settings
NO
Use current configuration
YES
Reset device to factory settings.
After confirming with the
function-button
, the display
shows:
IN,T DONE
Extended notes on the setting parameters:
#1 Operational depth:
max. depth in metres at which, with the mixture used (e.g.
Nitrox 32), the set maximum oxygen partial pressure "Po2"
(usually 1.4 bar) is reached.
#2 Air pressure:
is necessary for correct calibration and calculation.
#3 Max. Partial pressure: Due to the toxicity of oxygen, it is recommended not to be
exposed to an oxygen partial pressure above 1.4 bar. This
applies under optimal conditions and health. Depending on
the condition of the day and stress (e.g. cold water), this
limit should be reduced further down (e.g. 1.2 bar)!