GREER COMPANY
Crane Systems
GREER COMPANY, 1918 E. Glenwood Place, Santa Ana CA 92705 Telephone: (714) 259-9702. Fax: (714) 259-7626. PN W424102 REV C 09/99
MicroGuard
®
424 Installation Manual
14 of 35
CABLE 8
POWER AND FUNCTION KICK-OUT
4 CONDUCTOR 16 AWG SHIELDED
CABLE COLOR
FUNCTION
COMPUTER / TERMINAL
RED
POWER IN
B + / TB - 1
BLACK
GROUND
B - / TB - 1
WHITE
F.K.O +V IN
RL1 COMMON / TB - 7
GREEN
F.K.O +V OUT
RL2 NORMALLY OPEN / TB - 7
Note:
This system operates better with two separate power feeds
(one for the b+, the other for f.k.o. +v in.)
SYSTEM BY-PASS SWITCH
COLOR
SWITCH
FUNCTION
COMPUTER CON’N / TERMINAL
RED
COMMON
B
RL1 COMMON / TB - 7
BLACK
N/O
BY-PASS RELAYS WHEN CLOSED
RL1 NORMALLY OPEN / TB - 7
YELLOW
N/C
SIGNAL BY-PASS WHEN OPEN
DIN: 10 / TB - 5
A.T.B. BOARD CONNECTIONS
COLOR
BOARD LOCATION
COMPUTER CONNECTION /
TERMINAL
FUNCTION
RED
1
+ CL / TB - 7
SWG +DR (OUT)
BLACK
3
- CL / TB - 7
SWG -DR (OUT)
VIOLET
A.T.B LO
A.T.B IN / TB - 5
ATB SIGNAL
RED
+ 5V
+ 5VA / TB - 6
BOARD POWER
BLACK
0V
0V / TB - 4
BOARD GND.
WHITE
A.T.B OUT
DIN: 13 / TB - 5
ATB CONDITIONING
RED
2
+DR / TB - 3
SWG +DR (IN)
BLUE
4
-DR / TB - 3
SWG -DR (IN)
YELLOW
+VP
+VP / TB - 4
A.T.B SIG. PULL-UPS
WHITE
RL OUT
DOUT 1 / TB - 6
A.T.B KICK-OUT
ORANGE
A.T.B HI
NO CONNECTION