GREER COMPANY
Crane Systems
GREER COMPANY, 1918 E. Glenwood Place, Santa Ana CA 92705 Telephone: (714) 259-9702. Fax: (714) 259-7626. PN W424102 REV C 09/99
MicroGuard
®
424 Installation Manual
33 of 35
GREER COMPANY SERVICE DEPARTMENT RETROFIT CALIBRATION REPORT
COMPLETE AND RETURN A COPY TO GREER ALONG WITH THE BACKUP PERSONALITY
.
MACHINE
TYPE
MACHINE
SERIAL #
DUTY CHIP #
SYSTEM TYPE
DATE
COMPLETED
COMPUTER
DISPLAY
REEL
ANGLE
ATB SERIAL #
P/N:
P/N: P/N: P/N: MAIN
S/N:
S/N: S/N: S/N: JIB/
AUX.
1.
Zero Analog Sensors
TX0 ________/ _________
TX1 ________/ _________
Ain2 ________
Ain3 ________
2.
Span Analog Sensors
Ain2 __________ Ain3 _________
Check angle indication: act/ind. ________ /__________ __________/_________ _______/________
3.
Set Swing Pot or Check Swing Switches
, ________
4.
Pressure span
:
Actual load entered______________
Radius measured_______________
Indicated load__________________
5.
MAIN BOOM ONLY:
Radius / Moment
: Retracted low angle _______________measured radius ___________
High angle ______________measured radius ___________
Ind. length _____________
Mid extension low angle _______________measured radius ___________
High angle ______________measured radius ___________
Ind. length ______
Full extension low angle _______________measured radius ___________
High angle _______________measured radius ___________
Ind. length _______________
6.
Boom Deflection Correction
Actual load ________________
Measured radius ____________
Radius entered ______________ F value = ___________.
Indicated load _______________
7.
Annular gain test
__________