GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA  92705     Tel: 714) 259-9702    Fax: 714) 259-7626 PN W414107- 
MicroGuard

 414 System Lattice Boom Cranes Horizontal Display Clyde M4190 Barge Mount OPERATOR'S MANUAL    12/20/01 

9 of 21 

CRANE

SET  UP

WORKING

AREA

STOWED

1

2

3

4

5

6

7

UPPER RIGHT DISPLAY

DEDUCT

PUSH BUTTONS -- LAMPS -- ICONS

PUSH BUTTONS -- LAMPS -- ICONS

PUSH BUTTONS -- LAMPS -- ICONS

PUSH BUTTONS -- LAMPS -- ICONS

  

THE DISPLAY 

THE DISPLAY 

THE DISPLAY 

THE DISPLAY -- UPPER RIGHT

UPPER RIGHT

UPPER RIGHT

UPPER RIGHT    

RADIUS/HEIGHT 

RADIUS/HEIGHT 

RADIUS/HEIGHT 

RADIUS/HEIGHT       

shows the 

current radius and height. Height is 
displayed only when the push button 
is pressed and held.When the push 
button is not pressed, the read out  
is always shown as the radius of  
the load. 

PARTS

PARTS

PARTS

PARTS----OF

OF

OF

OF----LINE

LINE

LINE

LINE

 

(20)

 is used to 

view the current parts-of-line and to 
select the parts-of-line in use on the 
selected winch. 

WINCH (

WINCH (

WINCH (

WINCH (3)

3)

3)

3)

 identifies the winch 

currently selected. This button is 
used to alternate between the front 
and rear winch. When switching between winches, the parts-of-line previously selected and recorded for 
each winch will be displayed whenever a particular winch is selected. 

ANGLE/LENGTH

ANGLE/LENGTH

ANGLE/LENGTH

ANGLE/LENGTH

 

(4)

 provides a read out of angle or length. Length is displayed only when the push 

button is pressed and held. When the push button is not pressed, the read out is always shown as the 
Angle of the main boom. 

WORKING AREA

WORKING AREA

WORKING AREA

WORKING AREA (5

55

5) 

receives and displays messages. Messages received in this area will conform to 

the current duty selection and the swing position of the crane upper for cranes with swing and multiple 
working swing areas. 

TARE (6) 

TARE (6) 

TARE (6) 

TARE (6) 

extracts or "tares out" the weight of hook and slings. When pushed, this button will show the 

actual weight of the load being lifted without the weight of the hooks and slings.. 

TO SET

TO SET

TO SET

TO SET TARE

 TARE

 TARE

 TARE 

With the hook and slings lifted, press & hold the TARE button (6) for three seconds. The 

display console will then beep and "zero" the actual load display. The TARE lamp will then illuminate to 
indicate that a tare has been set. 

TO CLEAR TARE

TO CLEAR TARE

TO CLEAR TARE

TO CLEAR TARE

  Press the TARE button. The display console will immediately beep, the actual load 

display will show the total weight below the boom head, and the TARE lamp will be off. 

    

CRANE SETUP (7) 

CRANE SETUP (7) 

CRANE SETUP (7) 

CRANE SETUP (7) 

indicates the area of the display that provides a read out of the selected 

configuration. This icon is also a push button used to start the selection of the crane configuration.

 

TARE 

Summary of Contents for Microguard 414

Page 1: ...Barge Mount OPERATOR S MANUAL 12 20 01 1 of 21 MICROGUARD MICROGUARD MICROGUARD MICROGUARD 414 414 414 414 RATED CAPACITY INDICATOR RCI SYSTEM SYSTEM SYSTEM SYSTEM LATTICE BOOM CRANES LATTICE BOOM CRA...

Page 2: ...ontal Display Clyde M4190 Barge Mount OPERATOR S MANUAL 12 20 01 2 of 21 WARNING WARNING WARNING WARNING The MicroGuard 414 Rated Capacity Indicator System RCI for Lattice Boom Cranes Horizontal Displ...

Page 3: ...BLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS GENERAL WARNING 2 SYSTEM DESCRIPTION 4 THE DISPLAY UPPER LEFT 5 THE DISPLAY UPPER LOWER RIGHT 6 PUSH BUTTONS LAMPS ICONS 7 10 THE...

Page 4: ...f the crane capacity chart stored in the computer memory When an approaching overload or Two Block condition is sensed by the system audible and visual alarms activate This System can also be configur...

Page 5: ...ATED CAPACITY is the ROPE CAPACITY and the message ROPE LIMIT will appear in the information area 4 The BAR GRAPH 2 is an analog BAR GRAPH that shows the amount of crane capacity being used and the ra...

Page 6: ...ower safe working strength than the actual capacity the MAXIMUM RATED CAPACITY display will show the reduced capacity and the message ROPE LIMIT will be displayed in the information area WINCH IN USE...

Page 7: ...ble alarm has been reached or exceeded When the crane is equipped with function kick out this indicator will illuminate simultaneously for Overload Wire Rope Limit or an Anti Two Block condition Funct...

Page 8: ...8 7 3 5 2 1 4 6 VIEW SET CLEAR DOWN UP 9 10 11 12 13 PUSH BUTTONS LAMPS ICONS PUSH BUTTONS LAMPS ICONS PUSH BUTTONS LAMPS ICONS PUSH BUTTONS LAMPS ICONS THE DISPLAY THE DISPLAY THE DISPLAY THE DISPLAY...

Page 9: ...er a particular winch is selected ANGLE LENGTH ANGLE LENGTH ANGLE LENGTH ANGLE LENGTH 4 provides a read out of angle or length Length is displayed only when the push button is pressed and held When th...

Page 10: ...DUCT INDICATOR 2 DEDUCT INDICATOR 2 is an amber lamp that indicates erected deducts When a deduct is selected the lamp will illuminate to warn the operator that a deduct has been applied to the allowe...

Page 11: ...an ANTI TWO BLOCK ALARM or an OPERATOR SETTABLE ALARM The audible alarm may be canceled by pressing and releasing the CANCEL ALARM button The audible alarm remains canceled until the condition causing...

Page 12: ...matically registered when the button is released The number chosen applies only to the winch currently selected A value must be programmed for both winches WINCH WINCH WINCH WINCH The current selectio...

Page 13: ...N SELECTION CONFIGURATION SELECTION CONFIGURATION SELECTION START THE SELECTION OF CRANE CONFIGURATION BY PRESSING CRANE SET UP CRANE SET UP SCROLL TO AUXILIARY TIP OR AUX TIP NO ERECTED ATTACHMENTS O...

Page 14: ...This is achieved by means of minimum and maximum angle and maximum height alarms These alarms can be programmed for each job site and set rapidly for the prevailing site conditions thereby aiding the...

Page 15: ...NG ALARMS 1 FROM THE MAIN WORKING SCREEN PRESS VIEW TO ACCESS THE OPERATOR ALARM SCREEN NOTE SET OR CLEAR ALARMS ONLY FROM WITHIN THE ALARM SCREEN 2 WHEN ENTERING THE ALARM SCREEN THE CURSOR ARROW ALW...

Page 16: ...EN SETTING THE ALARMS SETTING THE ALARMS SETTING THE ALARMS SETTING THE ALARMS TO SET ALARM POINT POSITION THE CRANE AT THE POINT AT WHICH THE ALARM IS TO SOUND WHEN IN THE OPERATOR ALARM SCREEN PRESS...

Page 17: ...GHT EXCEEDS 75 FEET USE THE FOLLOWING PROCEDURE 1 EXTEND THE BOOM AND OR ADJUST THE BOOM ANGLE SO THAT THE TIP HEIGHT IS 75 FEET 2 PRESS VIEW TO ACCESS THE ALARM SCREEN THE CURSOR WILL BE AT MIN ANGLE...

Page 18: ...ALARMS CLEAR IS USED TO CANCEL A PREVIOUSLY SET ALARM ALARMS CAN ONLY BE CLEARED WHEN THE CURSOR IS POINTING TO THE ITEM TO BE CLEARED CANCELING OF ALARMS CAN BE CARRIED OUT REGARDLESS OF THE POSITION...

Page 19: ...FROM THE JIB SWITCH TO THE RECEPTACLE ON THE MAIN SWITCH 2 SET THE SELECTOR SWITCH TO BOTH 3 CHECK THAT RAISING THE WEIGHT AND TRIPPING THE SWITCH ON EITHER THE MAIN OR THE JIB SWITCH CAUSES THE A T...

Page 20: ...YED LOAD INCLUDES THE HOOK BLOCK AND ANY LIFTING ATTACHMENTS SUCH AS SLINGS PINS AND SHACKLES NOTE IF THE TARE FUNCTION HAS BEEN USED THE TARE LAMP WILL BE ILLUMINATED AND THE DISPLAYED LOAD WILL BE T...

Page 21: ...s Crane Systems Crane Systems Crane Systems GREER COMPANY 1918 East Glenwood Place Santa Ana CA 92705 Tel 714 259 9702 Fax 714 259 7626 PN W414107 MicroGuard 414 System Lattice Boom Cranes Horizontal...

Reviews: