The ERV must be located in a conditioned area where it will be possible to conveniently service the unit. The ERV would be located in the mechanical
room, above a drop ceiling or an area close to the outside wall where the weatherhoods will be mounted. Attic installations are not normally
recommended due to extreme temperatures variation, and difficulty in performing required service & maintenance. If an attic is selected, special care
should be taken in ensuring the unit will perform as intended. Unit may need to be protected with insulated shelter, built on site.
Connecting appliances to the ERV
It is not recommended, including:
• clothes dryer
• kitchen exhaust hoods
• combustion venting
• central vacuum system
These appliances may cause lint, dust or grease to collect in the ERV, damaging the unit or risk of hazard.
Connecting any of these type of appliances to the ERV will void warranty
LCH-H series has dual has access doors on the front and back. Also, the main electrical control panel may be moved from front to back allowing for
ducting layout.
OUTDOOR AIR CONNECTIONS
(COLD SIDE)
OUTDOOR AIR CONNECTIONS
(COLD SIDE)
INDOOR AIR CONNECTIONS
(WARM SIDE)
INDOOR AIR CONNECTIONS
(WARM SIDE)
Default Configuration. Unit may be easily reversed in field.
1. INSTALLATION
2. OPTIONAL REVERSIBLE APPLICATION
LCH-4E, LCH-7E, LCH-12E
Summary of Contents for LCH-12E
Page 14: ...14 LOW SPEEDS 90V 75V J4 J5 J6 12 WIRING DIAGRAM LCH 4E...
Page 15: ...15 LOW SPEEDS 90V 75V J4 J5 J6 13 WIRING DIAGRAM LCH 7E...
Page 16: ...16 LOW SPEEDS 90V 75V J4 J5 J6 14 WIRING DIAGRAM LCH 12E...
Page 32: ...32 12 SCH MA DE C BLAGE LCH 4E LOW SPEEDS 90V 75V J4 J5 J6...
Page 33: ...33 13 SCH MA DE C BLAGE LCH 7E LOW SPEEDS 90V 75V J4 J5 J6...
Page 34: ...34 14 SCH MA DE C BLAGE LCH 12E LOW SPEEDS 90V 75V J4 J5 J6...