Accuracy
Accuracy Table
(specified at 23
°
C
±
5
°
C (73
°
F
±
41
°
F)
Input Impedance: 1 M
Ω
Specifications
Display: 3-1/2–digit LCD (1999 maximum count)
Sampling Rate: Approximately 2 to 3 measurements per second
Range Overload Indication: “1” MSD displayed
Overvoltage Protection Category:
Category II, 300 VAC and 300 VDC
Operating Conditions: 0
°
C to 40
°
C (32
°
F to 104
°
F),
0 to 75% relative humidity
Storage Conditions: Remove battery
Pollution Degree: 2
Battery: 12 V battery (NEDA 1811A or IEC 3LR50)
Fuse: 200 mA/250 V F fuse, interrupting rating 1.5 kA, 5 x 20 mm
Function
Range
Accuracy
0 to 200 / 300 V
±
1.5%
0 to 2 / 20 / 200 / 300 V
±
0.8%
0 to 200 mA
±
2.0%
0 to 2 k / 20 k / 200 k / 2000 k
±
1.5%