![Greenlee DM-65 Instruction Manual Download Page 13](http://html1.mh-extra.com/html/greenlee/dm-65/dm-65_instruction-manual_2262539013.webp)
DM-65
13
Accuracy
Refer to the “Specifications” section for operating conditions and temperature coefficient.
Accuracy is specified as follows: ± (a percentage of the r a fixed amount) at 23 °C ± 5 °C
(73.4 °F ± 9 °F), 0% to 75% relative humidity.
Accuracy is specified from 5% to 100% of the range unless noted otherwise.
AC Voltage
DC Voltage
Range
(40 Hz to 400 Hz)
Accuracy
Range
Accuracy
6.000 V
± (0.8% + 0.005 V)
600.0 mV
± (0.8% + 0.5 mV)
60.00 V
± (1.2% + 0.05 V)
6.000 V
± (0.8% + 0.005 V)
600.0 V
± (1.2% + 0.5 V)
60.00 V
± (0.8% + 0.05 V)
1000 V*
± (1.2% + 5 V)
600.0 V
± (0.8% + 0.5 V)
Input Impedance: 10 MΩ, < 100 pF
1000 V*
± (1.0% + 5 V)
* 1000 V range is specified from 20% to 100%
of range.
Input Impedance: 10 MΩ, < 100 pF
* 1000 V range is specified from 20% to 100%
of range.
Resistance
Diode Test
Measuring Range: 2.000 V
Test Current (typical): 0.8 mA
Open Circuit Voltage (typical): < 3 V
Continuity
Tone Threshold: Between 20 Ω and 150 Ω
Range
Accuracy
600.0 Ω
± (1.0% + 0.5 Ω)
6.000 kΩ
± (1.0% + 0.005 kΩ)
60.00 kΩ
± (1.0% + 0.05 kΩ)
600.0 kΩ
± (1.0% + 0.5 kΩ)
6.000 MΩ
± (1.5% + 0.005 MΩ)
60.00 MΩ
± (3.0% + 0.10 MΩ)
Open Circuit Voltage: < 0.7 VDC
Summary of Contents for DM-65
Page 10: ...10 Typical Measurements Current Measurement AC Voltage Measurement DC Voltage Measurement ...
Page 12: ...12 Typical Measurements Temperature ...
Page 29: ...DM 65 29 Mediciones más comunes Temperatura ...
Page 36: ...36 ...
Page 47: ...DM 65 47 Mesures types Température ...
Page 54: ...54 ...
Page 63: ...DM 65 63 Typische Messungen Strommessung Wechselspannungsmessung Gleichspannungsmessung ...
Page 64: ...64 Typische Messungen Durchgangsprüfung Kapazitätsmessung Widerstandsmessung ...
Page 65: ...DM 65 65 Typische Messungen Diodenmessung Sperrvorspannung Durchlassspannung Temperatur ...