CM-1200
9
Operation
1.
Set the selector according to the settings table.
Settings Table
Electric shock hazard:
Contact with live circuits can result in severe injury or death.
* Tone indicates a circuit resistance is less than 100
Ω
.
** Frequency can also be measured with the jaw.
2.
See Typical Measurements for illustrations of typical uses.
3.
Test the unit on a known functioning circuit or component.
• If the unit does not function as expected on a known functioning circuit, replace the
battery.
• If the unit still does not function as expected, send the unit to Greenlee for repair.
To measure
set the
connect the
and the
this value …
selector to
red lead
black lead
this symbol …
to …
to …
Continuity*
K
Ω
V
Ω
COM
Current (AC)
A
.
N/A
N/A
Current (DC)
A
N/A
N/A
Frequency**
Hz
V
Ω
COM
Resistance
K
Ω
V
Ω
COM
Voltage (AC)
V
V
Ω
COM
Voltage (DC)
V
V
Ω
COM