93-70 Digital Multi-Tester
9
DC Current
Range
Resolution
Accuracy
Voltage Burden
200
µ
A
100nA
2mA
1
µ
A
±
(1.2% rdg. + 2 digits)
<0.7V
20mA
10
µ
A
200mA
100
µ
A
10A
10mA
±
(2.5% rdg. + 3 digits)
<0.3V
Overload Protection: 0.5A/250V Fuse, less than 200mA; 10A/600V Fuse for 10A Range
AC Current (40 Hz ~ 500 Hz)
200
µ
A
100nA
20mA
10
µ
A
±
(1.5% rdg. + 3 digits)
<0.7V
200mA
100
µ
A
10A
10mA
±
(3% rdg. + 1 digit)
<0.3V
Overload Protection: 0.5A/250V Fuse, less than 200mA; 10A/600V Fuse for 10A Range