855GX Electric Bender
Greenlee Tools, Inc.
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
18
BendWorks™ Software Troubleshooting
(cont’d)
Preprocess Errors
Explanation of Error
36
Bend Angle Too Big
ErrorCode.BendAngleToolSmall, 34359738368
Bend angle cannot be bigger than
90 degrees.
37
Bend Angle Too Small
ErrorCode.BendRadiusTooSmall, 68719476736
Bend angle cannot be smaller than
5 degrees.
39
Distance Too Small From
End Of Last Bend To End
Of Pipe
ErrorCode.DistanceTooSmallFromEndOfLastBendToEndOfPipe,
274877906944
The distance from the end of
the last bend to the end of the
run cannot be shorter than the
Coupling Depth.
40
Distance Too Small From
Start Of
Pipe To Start Of First Bend
ErrorCode.DistanceTooSmallFromStartOfPipeToStartOfFirstBend,
549755813888
The distance from the start of
the run to the start of the first
bend cannot be shorter than the
Coupling Depth.
41
Loop Run
ErrorCode.LoopRun, 1099511627776
The conduit run is in a loop.
42
Multiple Benders
Not Supported
ErrorCode.MultipleBendersNotSupported, 2199023255552
Multiple benders not supported.
43
Type Not Supported
ErrorCode.TypeNotSupported, 4398046511104
The conduit type is not supported.
44
Back to Back Bends
ErrorCode.BacktoBackBends, 8796093022208
Conduit Run cannot have back to
back bends. Distance between two
bends cannot be 0
Informational Messages
Explanation of Error
55
No Valid Split From
Either Direction
ErrorCode.NoValidSplitFromEitherDirection, 18014398509482000
No valid split from either direction.
Operation