8
H6200B / 42247 Chain Saw
Greenlee Textron / Subsidiary of Textron Inc.
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Specifications — Hydraulic Power Source (cont’d)
* 200 psi is the maximum agreed standard for the Hydraulic Tool Manufacturers Association (HTMA). Greenlee Fairmont
hydraulic tools will operate satisfactorily at this standard.
1.
Maximum hydraulic fluid temperature must not exceed 140
°
F (60
°
C) at the maximum expected ambient tem-
perature. A sufficient oil cooling capacity is needed to limit the hydraulic fluid temperature.
2.
Maximum hydraulic flow must not exceed 8 gpm. Install a flow meter in the return line to test the rate of hydraulic
flow in the system before working the tool.
3.
The pressure relief valve must not exceed 2000 psi @ 8 gpm. The pressure relief valve must be located in the
supply circuit between the pump and tool to limit excessive hydraulic pressure to the tool.
4.
Figure 3 shows a typical hydraulic power source being used with the tool.
Figure 3
Hydraulic Schematic
FILTER
(10 MICRON)
COOLER
RELIEF
VALVE
2000 PSI
CONTROL
VALVE
FLOW METER
T
P
TOOL
RESERVOIR
PUMP
POWER SOURCE
Recommended Hydraulic Fluids
Electrical shock hazard: Use only hydraulic fluid with dielectric properties when utilizing this tool near energized
electrical lines.
Failure to observe this warning could result in severe injury or death.
Any non-detergent hydraulic fluid which meets the following specifications or HTMA specifications may be used.
S.U.S. @ 100
°
F (38
°
C) ......................................................................... 140 to 225
@ 210
°
F (99
°
C) ...................................................................... 40 minimum
Flash Point ...................................................................... 340
°
F min (170
°
C min)
Pour Point ......................................................................... -30
°
F min (-34
°
C min)