General Information
Unit and System Identification Tags . . . . . . . . . . . 4
Pre-Installation Information . . . . . . . . . . . . . . . . . . 4
Electrical Disconnects . . . . . . . . . . . . . . . . . . . . . . 4
Moving Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Guards - Motor Cover or Inlet Guard . . . . . . . . . . 4
Inspection Door . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Air Pressure and Suction . . . . . . . . . . . . . . . . . . . . 4
Fans - Rigging and Lifting . . . . . . . . . . . . . . . . . . . 5
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . 5
UL/cUL Listed Smoke Exhaust . . . . . . . . . . . . . . . 6
Unit Start-Up
Visual Inspection of Equipment . . . . . . . . . . . . . . . 7
Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Additional Steps for Initial Start-Up . . . . . . . . . . . . 7
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . 7
Routine Maintenance and Operation
Fan Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Fasteners and Set Screws . . . . . . . . . . . . . . . . . . . 8
Direct Drive Fans . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Belt Drive Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
V-Belt Replacement . . . . . . . . . . . . . . . . . . . . . . . . 9
Alignment of Pulleys and Belts . . . . . . . . . . . . . . . 9
Field Coating Touch-Up Procedure for
Scratched Areas . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Variable Frequency Drive Operation . . . . . . . . . . 10
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance Log . . . . . . . . . . . . . . . . . . . Backcover
Our Commitment . . . . . . . . . . . . . . . . . . . Backcover
wipe clean with Tectyl
®
506 (Ashland Inc.) or the
equivalent. For hard to reach internal surfaces or for
occasional use, consider using Tectyl
®
511M Rust
Preventive, WD-40
®
or the equivalent.
Removing from Storage
As fans are removed from storage to be installed
in their final location, they should be protected and
maintained in a similar fashion until the fan equipment
goes into operation.
Prior to assembly and installation of the unit and
system components, inspect the fan assembly to
make sure it is in working order.
1. Check all fasteners, set screws on the fan,
propeller, bearings, drive, motor base and
accessories for tightness.
2. Rotate the fan propeller by hand and assure no
parts are rubbing.
3. Fans should not be lifted by the fan housing,
motor, motor cover, windband or accessories.