Table of Contents

General Safety Information  . . . . . . . . . . . . . . . . . . 1
 Receiving, Unpacking, Handling, Storage . . . . . . . 2
 Inspection and Maintenance During Storage  . . . . 3
 Removing from Storage . . . . . . . . . . . . . . . . . . . . . 3
General Information
 Unit and System Identification Tags  . . . . . . . . . . . 4
 Pre-Installation Information . . . . . . . . . . . . . . . . . . 4
 Electrical Disconnects . . . . . . . . . . . . . . . . . . . . . . 4
 Moving Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
 Guards - Motor Cover or Inlet Guard  . . . . . . . . . . 4
 Inspection Door . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
 Air Pressure and Suction . . . . . . . . . . . . . . . . . . . . 4
Fans - Rigging and Lifting . . . . . . . . . . . . . . . . . . . 5
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . 5
UL/cUL Listed Smoke Exhaust . . . . . . . . . . . . . . . 6
Unit Start-Up
 Visual Inspection of Equipment . . . . . . . . . . . . . . . 7
 Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
 Additional Steps for Initial Start-Up . . . . . . . . . . . . 7
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . 7
Routine Maintenance and Operation
 Fan Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
 Motors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Fasteners and Set Screws . . . . . . . . . . . . . . . . . . . 8
Direct Drive Fans . . . . . . . . . . . . . . . . . . . . . . . . . . 8
 Belt Drive Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
 V-Belt Replacement . . . . . . . . . . . . . . . . . . . . . . . . 9
 Alignment of Pulleys and Belts  . . . . . . . . . . . . . . . 9
Field Coating Touch-Up Procedure for  
 Scratched Areas . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Variable Frequency Drive Operation  . . . . . . . . . . 10
Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance Log . . . . . . . . . . . . . . . . . . . Backcover
Our Commitment . . . . . . . . . . . . . . . . . . . Backcover

wipe clean with Tectyl

®

 506 (Ashland Inc.) or the 

equivalent. For hard to reach internal surfaces or for 
occasional use, consider using Tectyl

®

 511M Rust 

Preventive, WD-40

®

 or the equivalent.

Removing from Storage

As fans are removed from storage to be installed 
in their final location, they should be protected and 
maintained in a similar fashion until the fan equipment 
goes into operation.

Prior to assembly and installation of the unit and 
system components, inspect the fan assembly to 
make sure it is in working order.

1.  Check all fasteners, set screws on the fan, 

propeller, bearings, drive, motor base and 
accessories for tightness.

2.  Rotate the fan propeller by hand and assure no 

parts are rubbing.

3.  Fans should not be lifted by the fan housing, 

motor, motor cover, windband or accessories.

Summary of Contents for TAUB

Page 1: ...without striking or rubbing any stationary objects 3 Motor must be securely and adequately grounded 4 Do not spin fan propeller faster than max cataloged fan RPM Adjustments to fan speed with a Variab...

Page 2: ...dity atmosphere which is sealed to prevent the entry of blowing dust rain or snow Temperatures should be evenly maintained between 30 to 110 F 1 to 43 C wide temperature swings may cause condensation...

Page 3: ...ulleys and Belts 9 Field Coating Touch Up Procedure for Scratched Areas 10 Variable Frequency Drive Operation 10 Parts List 11 Maintenance Log Backcover Our Commitment Backcover wipe clean with Tectyl...

Page 4: ...well as containing speci c information unique to the unit When contacting your local manufacturer s representative with future needs or questions have the information on this label available Tags are...

Page 5: ...ousing through a hole provided below the belt tube opening The electrical supply line should then be either 1 connected to an optional service disconnect switch or 2 wired directly to the motor For be...

Page 6: ...mentation lectrique en position Arr t avant tout contr le ou entretien Faire preuve de pr caution pour travailler au voisinage des l ve registres liaison fusible Ils peuvent lib rer les registres de f...

Page 7: ...n may be investigated Verify electrical conformance to speci cations Unauthorized alterations and unauthorized backcharges will not be recognized by manufacturer After the fan has been installed and a...

Page 8: ...lity lithium based grease Those operating outside these temperatures require special high or low temperature grease If contamination or high moisture conditions exist more frequent lubrication is requ...

Page 9: ...c operating condition Changing V belt drive components could result in unsafe operating conditions which may cause personal injury or failure of fan components 1 Remove the protective coating from the...

Page 10: ...f affected area to be repaired using medium sandpaper provided or medium Scotch Brite pad Feather the edges 2 Clean affected area to be touched up using an alkaline based cleaner and rinse 3 Apply Kem...

Page 11: ...fore taking any corrective action make certain unit is not capable of operation during repairs Outlet Screen optional Propeller Shaft Pulley Shaft Bearings Bearing Cover Fan Shaft Windband Fusible Lin...

Page 12: ..._____________ AM PM Notes __________________________________________ ________________________________________________ ________________________________________________ _________________________________...

Reviews: