Variable Frequency Drive 
Operation

For operation with a variable frequency drive (VFD) 
always check motor amps when adjusting the 
operating frequency. Motor may be sized for the 
original selected operating speed under 60 Hz. 
Bypassing the VFD or increasing the speed from this 
original selection, even if less than 60 Hz, may cause 
motor to overload or fail. Consult factory with fan 
serial number before increasing the upper limiting 
frequency. 

Always check the fan RPM when adjusting the 
operating frequency. Do not exceed maximum class 
fan RPM of the propeller.

NOTE

It is the responsibility of the installing body to 
perform coast-down tests and identify any resonant 
frequencies after the equipment is fully installed. 
These resonant frequencies are to be removed 
from the operating range of the fan by using the 
“skip frequency” function in the VFD programming. 
Failure to remove resonant frequencies from the 
operating range will decrease the operating life of 
the fan and void the warranty.

Field Coating Touch-Up Procedure 
for Scratched Areas

Standard coating and color is RAL 7023 Concrete 
Grey. This procedure outlines the correct method for 
repairing minor scratches in the coating.

1.  Scuff affected area to be repaired using medium 

sandpaper (provided) or medium Scotch Brite™ 
pad. Feather the edges.

2.  Clean affected area to be touched up using an 

alkaline based cleaner and rinse.

3.  Apply Kem Kromik

®

 primer using 1 inch foam 

brush (provided). Follow technical data sheet 
instructions.

4.  Allow primer to dry a minimum of 2-1/2 hours 

before top coating.

5.  Apply topcoat with industrial enamel using 1 inch 

foam brush (provided). Follow technical data 
sheets instructions. Allow painted units to air-dry 
and cure before putting into service. See Technical 
Data sheets (included with kit) for detailed drying 
and cure schedules at different temperatures.

To order coating repair kits please reference part 
number HAZ2597 PNT FIELD REPAIR KIT, RAL 7023 
CONCRETE GREY. Please contact factory with your 
fan’s serial number for colors other than our standard.

TOUCH-UP PAINT REPAIR KIT CONTENTS

 •  One pint of Kem Kromik

®

 primer  

  - including a technical data sheet

 •  One pint of industrial enamel 

  - including a technical data sheet

  • Four disposable foam brushes
  • One sheet sandpaper
  • Repair procedure details

NOTE

While the manufacturer provides heavy-duty, quality 
products for marine environments, routine paint 
touch-ups may be required in coastal regions where 
salt or marine air could damage the coating. The 
severe environment will accelerate the damage from 
any scratches or chips and it is recommended that 
those be repaired immediately.

Summary of Contents for TAUB

Page 1: ...without striking or rubbing any stationary objects 3 Motor must be securely and adequately grounded 4 Do not spin fan propeller faster than max cataloged fan RPM Adjustments to fan speed with a Variab...

Page 2: ...dity atmosphere which is sealed to prevent the entry of blowing dust rain or snow Temperatures should be evenly maintained between 30 to 110 F 1 to 43 C wide temperature swings may cause condensation...

Page 3: ...ulleys and Belts 9 Field Coating Touch Up Procedure for Scratched Areas 10 Variable Frequency Drive Operation 10 Parts List 11 Maintenance Log Backcover Our Commitment Backcover wipe clean with Tectyl...

Page 4: ...well as containing speci c information unique to the unit When contacting your local manufacturer s representative with future needs or questions have the information on this label available Tags are...

Page 5: ...ousing through a hole provided below the belt tube opening The electrical supply line should then be either 1 connected to an optional service disconnect switch or 2 wired directly to the motor For be...

Page 6: ...mentation lectrique en position Arr t avant tout contr le ou entretien Faire preuve de pr caution pour travailler au voisinage des l ve registres liaison fusible Ils peuvent lib rer les registres de f...

Page 7: ...n may be investigated Verify electrical conformance to speci cations Unauthorized alterations and unauthorized backcharges will not be recognized by manufacturer After the fan has been installed and a...

Page 8: ...lity lithium based grease Those operating outside these temperatures require special high or low temperature grease If contamination or high moisture conditions exist more frequent lubrication is requ...

Page 9: ...c operating condition Changing V belt drive components could result in unsafe operating conditions which may cause personal injury or failure of fan components 1 Remove the protective coating from the...

Page 10: ...f affected area to be repaired using medium sandpaper provided or medium Scotch Brite pad Feather the edges 2 Clean affected area to be touched up using an alkaline based cleaner and rinse 3 Apply Kem...

Page 11: ...fore taking any corrective action make certain unit is not capable of operation during repairs Outlet Screen optional Propeller Shaft Pulley Shaft Bearings Bearing Cover Fan Shaft Windband Fusible Lin...

Page 12: ..._____________ AM PM Notes __________________________________________ ________________________________________________ ________________________________________________ _________________________________...

Reviews: