7

air Filter Gauge

Indicates when filters become 
dirty. An indicator light may be 
wall/beam mounted or provided 
with a remote control panel.

Motorized dampers

Discharge dampers are available 
to prevent backdrafts when 
the fan is not in operation. 
Mixing box dampers are factory 
mounted and wired.

Fan spring Vibration Isolation

Spring vibration isolators are available in lieu of 
neoprene isolators for housing sizes H22 and H32   
(fan sizes 112 and larger).

115 Volt service receptacle

A 115 volt GFCI outlet is mounted externally in a NEMA 
3R box for the convenience of field service personnel. A 
separate 115 volt power source is required.

roof curbs

Factory provided roof 
curbs are available to 
ensure compatibility 
between make-up air 
unit and roof curb. 
Standard construction is 
G90 galvanized steel.

special coatings

Greenheck’s Permatector powder paint is available if a 
painted look is desired and recommended for outdoor 
installations near salt water shorelines. Decorative 
baked enamel paints are also available in a variety of 
colors to match existing building fixtures. Consult your 
Greenheck representative for paint selections.

Weatherhood

A galvanized steel mist eliminating intake hood 
is standard on outdoor IGX-HV models. The mist 
eliminating intake hood provides a double layer of 
protection against moisture entering the mixing box 
section.

Propane Gas conversion Kit

Greenheck’s indirect gas furnaces are ETL listed for 
both Natural Gas or LP.

duct adapter

Duct adapters are optional with factory supplied curbs 
and provide an easy method for attaching ductwork to 
the curb.

double Wall construction

An interior metal liner is available to isolate insulation 
from the airstream. One-inch thick insulation is included 
with this option.

Gas Pressure regulator

Required if building gas line pressure 
exceeds IGX-HV maximum inlet gas 
pressure of 14 in. wg.

smoke detector

A 12/24 VDC Photoelectric smoke detector is available 
for duct mounting. Typical operating temperature range 
is 32°F to 131°F (0°C to 55°C).

discharge diffuser

Available as either 3-way 
diffuser for horizontal 
discharge or 4-way 
diffuser for downblast 

discharge.

airstream override

This option prevents the discharge air temperature 
from dropping below 55°F after the call for heating has 
ended.

Warm-up control

Available with the TC5 
thermostat. The thermostat 
may be programmed to 
provide a warm-up cycle prior 
to the occupied start time. This 
ensures immediate comfort 
and proper air quality as people enter the occupied 
areas.

accessorIes

3-Way Diffuser

Summary of Contents for IGX-HV

Page 1: ...Modular Heating Ventilating Unit Model IGX HV Indirect Gas Fired Heating Evaporative Chilled Water DX Cooling October 2008...

Page 2: ...s steel heat exchanger Direct spark ignition system Easy access burner controls ETL listed to ANSI Standard Z83 8 Solid state automatic ignition module Vibration Isolators The entire fan and motor ass...

Page 3: ...cooling The Intelligent Fan feature energizes the fan continuously during occupied mode and intermittently with a call for heating or cooling in unoccupied mode TC3 2 Stage Heating 2 Stage Cooling TC...

Page 4: ...Like the MB2 option this option is appropriate for applications that call for a building automation system that will control the mixing box dampers MB4 Manual Quadrant The MB4 option consists of a man...

Page 5: ...ng section includes the cooling coil stainless steel drain pan and insulated double wall construction Drain and coil connections are stubbed through the wall for convenience For proper coil sizing use...

Page 6: ...1 3 000 RPM 1014 1097 1172 1244 1315 1386 250 BHP 1 22 1 39 1 55 1 72 1 88 2 05 MODEL CFM TOTAL STATIC PRESSURE in inches of WG Maximum Furnace Size Input MBH 0 50 0 75 1 00 1 25 1 50 1 75 IGX HV 112...

Page 7: ...mist eliminating intake hood is standard on outdoor IGX HV models The mist eliminating intake hood provides a double layer of protection against moisture entering the mixing box section Propane Gas C...

Page 8: ...d for a minimum of 150 of driven horsepower Pulleys shall be cast and have machined surfaces 10 horsepower and less shall be supplied with an adjustable drive pulley Electrical All internal electrical...

Reviews: