Problem

Cause

Corrective Action

Excessive noise

Wheel unbalance

Clean all dirt off wheel. Check wheel balance, replace if 
necessary.

Impeller blocked

Inspect and remove debris from inlet and outlet.

Fan doesn’t operate

Electrical supply

Check fuses/circuit breakers. Check for switches turned 
off or disconnected. Check for correct supply voltage.

Control signal

Verify control signal and wiring. Check connections to 
terminal strip.

Low airflow

Inlet / outlet blocked

Remove debris from inlet and outlet.

*  Excessive fan speed may overload the motor and result in motor failure. Do not exceed the maximum cataloged 

rpm of the fan.

Troubleshooting

Figure 7 – GJI wiring diagram

Terminal Strip

Disconnect  

Switch

Motor Connections

Summary of Contents for GreenJet GJI

Page 1: ...el should have a clear understanding of these instructions and should be aware of general safety precautions Improper installation can result in electric shock possible injury due to coming in contact...

Page 2: ...utions need to be taken to prevent deterioration of the unit during storage The user assumes responsibility of the unit and accessories while in storage The manufacturer will not be responsible for da...

Page 3: ...on safety practices involving industrial and commercial fans please refer to AMCA Publication 410 Electrical Disconnects Fan is provided with an integrated service disconnect Service disconnects shall...

Page 4: ...using vibration isolators Anchor Ceiling Fan Rail Washer 3 8 inch MAX rod nut and washer mounting hardware by others 20 00 27 56 Mounting Holes Qty 4 Figure 1 Top view of GJI mounting hole locations...

Page 5: ...requires either a 0 10VDC or MODBUS signal to control the fan speed Particular attention should be given when connecting power to the unit Supply wiring must be properly fused and conform to local an...

Page 6: ...6 General example for MODBUS device connection Recommended Wire Types 1 CAT5 CAT7 cables 2 J Y St 2x2x0 6 telephone wire 3 AWG22 2x2 twisted pair When using telephone flex with four cable cores it is...

Page 7: ...US communication Settings made in this register will be made active after a device reset or by entering a PIN code press h0 Access necessary PIN protection level RW NV 1 Minimal value 0 Maximum value...

Page 8: ...describing the equipment fan performance available accessories and specification data Problem Cause Corrective Action Excessive noise Wheel unbalance Clean all dirt off wheel Check wheel balance repl...

Reviews: