GreenFlux Dual Socket Smart Charging Controller
page - 17 -
©GreenFlux Assets B.V.
–
All rights reserved.
Installation Manual; version 4.6; 2019-11-05
Doc.nr. GFX.2017.14201807
RS485
EKM
Metering
Omnimeter
Pulse UL
v.4
Connect via Modbus. Meter
is set up in the software.
Note
: special EKM serial
communication is used.
10
RS485
Konect 1.4
Connect via Modbus. Meter
is set up in the software.
11
RS485
CET PMC-
340
Connect via Modbus. Meter
is set up in the software.
12
RS485
Carlo
Gavazzi
EM111
Connect via Modbus. Meter
is set up in the software.
13
RS485
Eastron
SDM230
Connect via Modbus. Meter
is set up in the software.
14
RS485
Iskra
WM3-6
Connect via Modbus. Meter
is set up in the software.
15
RS485
Schrack
MGRZK465
Connect via Modbus. Meter
is set up in the software.
16
Furthermore, the communication configuration settings on the meter itself need
to be set to the correct value, please check the manual of the meter manufacturer
for instructions on how to do this.
BRAND
BAUD
RATE
BYTE
SIZE
PARITY
STOP BITS
ADRES
ABB B23
19200 8
EVEN
1
1
Carlo
Gavazzi
EM24DIN
9600
8
NONE
1
1
Pulse (S0)
-
-
-
-
-
EASTRON
SDM630
9600
8
NONE
1
1
Carlo
Gavazzi
EM340
9600
8
NONE
1
1
Phoenix
Contacts
EEM350
9600
8
NONE
1
1
Tele S6
XM50A
1000VM
9600
8
NONE
1
1
Tele S9
XM300A
1000VM
9600
8
NONE
1
1
EKM
Omnimeter
Pulse UL v.4
Modbus
9600
8
NONE
1
1
Summary of Contents for T2235-02