1.0 INTRODUCTION 

These installation, operation, and maintenance instructions describe how the greenfan® 
bipolar ionizer shown in 

Figure 1

 is installed, operated, and maintained in the following 

field installation configurations: 

  on a fan of a Heating, Ventilating, Air Conditioning (HVAC) system behind an 

access panel or a cover; 

  on a fan of an air purifier behind the cover; and 

  on a ventilation fan behind a protective grill. 

The product may also be installed by a manufacturer inside the HVAC system, inside 
the air purifier, or inside the fan.

 

 

 

Figure 1. Three quarter view of greenfan® bipolar ionizer 

 

The greenfan® bipolar ionizer shown in 

Figure 1 

is an Intertek® ETL listed product and 

tested by Intertek® to conform to UL STD 867 and is certified to CSA C22.2 #187. 
Intertek® tests verified the 24-hour Time Weighted Average (TWA) ozone for this 
product is 0.0 parts per million by volume (ppmv) when tested in a 30 m3 chamber.  
The product is CARB certified and meets the Intertek® Sustainability Verified Zero 
Ozone program, meets UL 2998, and does not emit more than 0.005 ppm as tested per 
UL 867.

1

 The product is marked as 24 Volts Alternating Current (VAC) for installation in 

a Class 2 circuit. 
 
The greenfan® bipolar ionizer unit is typically installed at the fan inlet to provide the 
highest concentration of positive and negative ions to neutralize odors and aerosol 
pathogens in the volumetric airflow passing through the fan.

2

 Laboratory tests by 

 

 

1

 https://sustainabilitydirectory.intertek.com/images/certificates/524d5be7-1210-47b4-a0bc-

c138d316eb3c/ZOZ-90160-2022a.pdf 

2

 The greenfan® bipolar ion concentration is approximately 200 million ions per cubic centimeter (ions/cc) 

at the carbon fiber electrodes and varies depending on installation and environment conditions and 
declines based on the volumetric airflow and distance from the carbon fiber electrodes. 

Summary of Contents for 1600-01

Page 1: ...odel 1600 01 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Intertek Verified Zero Ozone Meets UL 2998 CARB Certified Certified to CSA C22 2 187 Conforms to UL 867 LAB TESTED US Patent 11173226 a...

Page 2: ...Fan Verification of Proper Operation 7 5 0 AIR PURIFIER INSTALLATION 7 5 1 Air Purifier Mechanical Installation 7 5 2 Air Purifier Electrical Installation 7 5 3 Air Purifier Verification of Proper Ope...

Page 3: ...e Weighted Average TWA ozone for this product is 0 0 parts per million by volume ppmv when tested in a 30 m3 chamber The product is CARB certified and meets the Intertek Sustainability Verified Zero O...

Page 4: ...lar ionizer NOTICE The greenfan bipolar ionizer should only be installed and used as directed in this installation manual or the 2 page tri fold manual supplied with the product Please read the entire...

Page 5: ...For air purifiers or ventilation fans disconnect power or unplug power cord before installation All field wiring must be in accordance with the National Electrical Code NEC or National Fire Protection...

Page 6: ...polar ionizer installation at fan inlet of an HVAC system f Install bipolar ionizer on metal shroud and with at least one inch clearance between electrodes and metal surfaces Make sure screws do not i...

Page 7: ...VAC control signal wires install 120 208 240V to 24VAC Class 2 UL listed transformer Model 1601 01 shown in Figure 8 and Figure 9 Connect 120 208 240V common wire of transformer to 120 208 240V common...

Page 8: ...eenfan bipolar ionizer Model 1600 01 2022 greenfan inc 6 Figure 8 Bipolar ionizer installed with 120 208 240V to 24VAC transformer Figure 9 Installation schematic with 120 208 240V to 24VAC transforme...

Page 9: ...hrough holes in flanges on either side of unit with at least one inch clearance between carbon fiber electrodes and metal surfaces to ensure airflow over both electrodes Install greenfan bipolar ioniz...

Page 10: ...nergized or turned on e After completing all steps of the air purifier mechanical and electrical installation proceed to air purifier verification of proper operation 5 3 Air Purifier Verification of...

Page 11: ...th fan rotation c After completing all steps of mechanical installation proceed to electrical installation Figure 12 Bipolar ionizer installed at inlet of ventilation fan behind protective grill 6 2 V...

Page 12: ...usly illuminated when thermostat fan switch air purifier or fan is turned to the ON position then bipolar ionizer is operating properly The greenfan bipolar ionizer continuously monitors high voltage...

Page 13: ...lity Verified Zero Ozone This product meets UL 2998 and does not emit more than 0 005 ppm as tested per UL 867 d CAUTION HIGH VOLTAGE This equipment should be inspected frequently and collected dirt r...

Page 14: ...oduct at the time of original purchase and GREENFAN shall not be liable for any direct indirect consequential or incidental damages arising out of the use or inability to use the product An RMA is req...

Page 15: ...5 x 104 TCID50 ml achieving a 97 6 reduction within 60 minutes 74 5 reduction within 30 minutes and 45 reduction within 15 minutes when installed on the inlet of a blower fan circulating air in a 20 x...

Reviews:

Related manuals for 1600-01