44
TORQUE ADJUSTMENT
This setting is used to set the torque and select the operating mode. Large screws and hard materials require a higher
torque setting than soft surfaces and small screws.
To adjust the torque turn the torque adjustment ring as required. Each click in a clockwise direction means an increase
in the torque produced. The highest position is for drill mode and is indicated by the drill icon. Turning the ring
counterclockwise will decrease the trosion produced.
LOADING
To charge the battery, the charger must be connected to the mains socket and the mains socket must be connected to
the battery via the cable. When you connect the charger to the battery the red light indicator on the charger will light
up, this means that it is charging, when the red light goes out it means that the battery is already full.
The battery contains a key to visualize its status through the illumination of three green LED lights. When the battery
is discharged the indicator light will not come on.
MAINTENANCE
•
Use a damp cloth with water and some mild soap to clean the tool. Never allow liquids to enter the interior.
•
Do not allow dust and dirt to enter the air vents.
•
Do not use solvents that may damage plastic parts.
•
It is not necessary to grease the drill bit.
TROUBLESHOOTING
The table includes some of the most common problems, their causes and remedies.
NOTE:
If you are unable to resolve the problem, please contact the Official Technical Service.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Drill does not
turn on
• The battery is not properly installed.
• The battery is not charged.
• Insert the battery again.
• Check battery charging requirements.
Battery does not
charge
• The battery is not properly inserted
into the charger.
• The charger is not plugged in.
• Ambient temperature is too hot or
too cold.
• Connect the battery to the charger until the
red light is on.
• Plug the charger into a working outlet.
• Move the charger and battery to an
ambient temperature above 4.5°C or below
40.5°C.
Drill suddenly
shuts down
• The battery has reached the
maximum thermal limit.
• No more load.
• Wait for the battery to cool down.
• Put it in the charger and charge it.
GREENCUT_TD210L_1010047_ES_FR_IT_EN_DE.indd 44
29/10/18 17:18