background image

RANGEXT  22 – TECHNICAL DOCUMENTATION 

  Page 10 

 

 

Circuit diagram 

Connection Diagram: 
 

 

 

 

Summary of Contents for RANGE XT 22

Page 1: ...the charging station and any changes to the configuration must be done by a qualified electrician and must comply with local regulations and laws for safety in the use of electricity Failure to comply with the regulations in this manual will result in the end the warranty period ...

Page 2: ...Wiring 9 3 COMMISSIONING 11 3 1 Opening the Range XT 22 housing 11 3 2 Changing the charging current 12 3 3 Charging station configuration 13 3 4 Emobility Cockpit connection 14 4 USAGE OF THE STATION 17 4 1 Description of the station 17 4 2 Sockets and Cables 18 4 3 Charging states 18 5 MAINTENANCE 21 5 1 Troubleshooting 21 5 2 Cleaning or replacing the filters 22 5 3 Support 23 ...

Page 3: ...on Control of access RFID App SMS Scan Charge Network interface Ethernet cable 3G 4G Remote management Software management system eMobility Cockpit online ENVIRONMENTAL Operating temperature 25 C to 45 C Altitude Up to 2000 m 6500 ft Setting Wall Column indoor or outdoor Humidity 95 relative humidity MECHANICAL Dimensions 520 x 630x 265mm Weight 55 kg Housing material Stainless steel Cooling Fan c...

Page 4: ...g station Fixing with 4 stainless steel screws M6 according to the following diagram and depending on the material of the wall Screw through the charging station When fixing with the 4 screws M6 do not forget the flat washers Drilling hole in the metal enclosure or making any modification not described or authorized in the present document will end the warranty of the product ...

Page 5: ... snow or objects from blocking the in and outlet The cable support shall be mounted at a height comprised between 1 and 1 1m from the ground level for optimal accessibility It can be mounted freely to the right or the left side of the charging station depending upon site configuration and user preferences considered the 300mm free space for the air inlet and outlet Please take all precautions for ...

Page 6: ... minimum of two people Fix the column on the concrete base with 4 threaded rods M10 according to the following diagram Do not forget the flat washers Electrical introduction is done through the left opening size 100x50mm with 1600 mm cable Bottom view Concrete base 700 x 400 x 150 mm Electrical introduction Electrical cable ...

Page 7: ...eel screws M6x10 and flat washers Drill 2x Ø7 hole or push the pre cutting hole under the cabinet and clean the metal shavings Fix with 2 stainless steel screws M6x10 with 4 serrated lock washers 4 flat washers and 2 prevailing torque type hex lock nuts Please make sure the emergency button is well protected and not damaged during the installation Emergency button ...

Page 8: ...ion on the placement of the Range XT 22 charging stations with respect to parking spaces Optimal placement As show in the figure here below we recommend installing the Range XT 22 front and center of the parking space and each charging station should serve one parking space Alternative placements Range XT 22 Range XT 22 Range XT 22 Range XT 22 Range XT 22 Range XT 22 Range XT 22 1 2 3 Range XT11 2...

Page 9: ...connected directly to the Mains Grid there is no need of Earth Fault Current Breaker 1 These sections must be re assessed by the installer according to the length 2 The Installer must define the types of Circuit breaker The circuit breakers at panel of 40 A and the power cable minimal cross section of 10 mm2 is overvalued in order to ensure the functioning of the charging station with a temperatur...

Page 10: ...RANGEXT 22 TECHNICAL DOCUMENTATION Page 10 Circuit diagram Connection Diagram ...

Page 11: ...the main converter box can lead to electric shock hazards Please make sure to carefully read instructions In case of a doubt please immediately contact Green Motion support 3 1 Opening the Range XT 22 housing Use a TR20 screwdriver to unscrew the 2 screws located on the top and the bottom right side of the Range XT front door The front door can be opened sideway Electric shock hazard In case of an...

Page 12: ...se working under voltage shall be avoided The electrical cable must reach the terminal from the left The electrical cable and the communication cable can be introduced into the Range XT housing from the bottom left side 1 2 or from the rear left side 3 The electrical connection is made on the power supply terminals located at the bottom of the charger See in blue circle Please measure the rotating...

Page 13: ...GMCU MPb board The board is located on the door of the converter enclose in front of the screen JP1 CAN Termination 22kW configuration shall only be used on 22kW chargers S2 OFF ON 1 Offline Online Offline Online 2 RFID Reader No Yes 3 CAN slave No Yes 4 AC DC AC DC 5 CCS Combo No Yes 6 CHAdeMO No Yes 7 DC 22kW No 22kW 8 AC T23 No Yes JP1 S2 ...

Page 14: ... router is located on the Range XT door Router Configuration The configuration is performed on the Green Motion Manufacturing Plan Teltonika RUTX09 modem router configuration Default settings IP 192 168 1 1 User admin Password admin01 The router requires a password change during the first start Please contact Green Motion SA support for the password ...

Page 15: ... 168 52 1 If a step by step configuration menu Setup Wizard appears you must ignore it and go directly to the menus described below Go to the Network WAN menu Activate and edit the MOB1S1A1 network If necessary enter the APN and the PIN code of the SIM card APN shared m2m ch Press Save Apply Please contact Green Motion SA support for the password ...

Page 16: ...pears it must be closed Go to the Network WAN menu Activate the WAN network and deactivate the other networks Press Save Apply o Authorize the management of the router from the WAN Only if in a private network Go to System Administration Access control Check Enable Remote HTTP and Enable Remote HTTPS Please contact Green Motion SA support for the password ...

Page 17: ...reen display 3 RFID reader 4 LED display 5 Emergency stop button To start a charge simply connect the car to the appropriate socket To switch on the Model either via the button offline charging station via the RFID card offline and online via the mobile app online stations only or via a SMS online stations only ...

Page 18: ...When you have authenticated on the Range XT 22 for the CHAdeMO plug you must select the plug icon on the screen it is mandatory Plug type icon shows as below CCS EU CHAdeMO 4 3 Charging states Button indicator Button Status display Comments No light Not powered or start up stage Green light on Ready to be use or need user interaction Blue light on Charge initialization vehicle charging or charge f...

Page 19: ...ments Green light on Ready to be use Flashing green light Start up stage Breathing green light Waiting for user interaction Flashing blue light Charge start up stage Breathing blue light Vehicle in charge Blue light on Vehicle charged Red light on Error in charging No light Stopped or not powered 50 of charge 100 of charge 50 100 ...

Page 20: ... to operate In this section you will find the information to start your experience LED Display status display Splash screen Touch the screen to wake up Authentication screen Before any operation please ensure that the 4G sign is colored in blue If bar graph is RED there is no connection to the server By touching the Flag you can choose your language Present the RFID badge on the RFID reader to ini...

Page 21: ...he charging station visual indicators are red Try to disconnect the car from the charging station and retry Check the emergency button it should be pull out Antenna bar graph is red Check that the connection of the Range XT to the backend is available network is available Authentication refused Check that you are a recognize and authorized user subscribed to the charging point operator database Ch...

Page 22: ...filters are checked on a yearly basis to ensure they are not obstructed and working properly In case of obstruction filters need to be replaced immediately Filters can be replaced They are accessible as described below Using a 2 5 mm hex key remove the 2 screws attaching each filter cartridge to the unit The filters are located inside the filter cartridge Contact Green Motion support for spare fil...

Page 23: ...pport is available Monday to Friday from 08 00 to 12 00 and from 13 00 to 17 00 16 00 on Friday CET Email support greenmotion ch Tel 41 21 544 04 46 Green Motion Ltd Chemin de Maillefer 61 1052 Le Mont sur Lausanne Switzerland GreenMotionEV com info greenmotion ch 41 0 21 544 04 44 ...

Reviews: