EN / 13
Connected devices do not work and the green LED indicator does light up.
CAUSE
SOLUTION
Overload shut off due to too high exceeding power of
the connected devices compared to the power of the
inverter.
Use devices that can’t exceed the inverter’s rated power.
Overload shut off due to too high peak power of the
connected devices lower then the power of the inverter.
Since the peak power of the electric appliances exce-
eds the peak power of the inverter, use an appliance
with a peak power consistant with the inverter.
The battery is over discharged (inverter gives a sound
alarm).
Replace the battery or use battery charger to charge
your battery.
Over temperature shut off due to bad ventilation.
Turn the inverter off and let it cool for 15 minutes. Wipe
the fan of the inverter clean as well as the whole inver-
ter. Place the inverter in a cool place. reduce load accor-
ding to requirements. Restart.
Too large input current.
Check the working state of the charging system. Make
sure the output voltage of the battery is within the
proper voltage range.