‘Orion Range’

Infra-red Microwave Presence Detector- Adjustable 

Model: ODM201

Important Safety Instructions

Please read these instructions carefully before installation and keep safe for future 
reference.

IMPORTANT

This product should be installed by a competent person and in accordance with the 
current IET Wiring Regulations and Building Regulations. 

If in doubt,consult a qualified electrician.

Always turn off the mains supply before commencing work.

Our range of PIR microwave presence detectors are designed to reduce the amount of time

lighting is left on unnecessarily, for example if an area is unoccupied or if there is sufficient 

natural light. 

A presence detector monitors the detection zone for occupancy, using radio waves in the

microwave band (5.8 GHz) if a person is sensed then the detector will automatically turn the

lighting on. When the area is vacated, the lighting will turn off after a preset time delay. Most 

of our microwave sensors have a built in light level (lux) sensor which will keep the lighting off 

if there is enough natural light available.

Controlling lighting with a presence detector can save up to 60% of lighting energy costs

dependent on occupancy behaviour and the amount of natural light available; our

microwave sensors can also be used to control heating and ventilation.

As this detector uses microwaves, detection is possible through plastic, glass and thin walls

such as office partitions. It will not detect movement through brick, concrete or metal.

TESTING

Dia:3

1. Turn ‘Time’ control fully anti-clockwise, ‘Lux’ control fully clock wise and ‘Sens’ control fully

clockwise  refer to Dia:3.

Dia:1

Dia:2

Switch the mains supply OFF first to prevent electric shock.

INSTALLATION

1. Decide on mounting position of sensor 

in and screw into position using the two 

mounting lugs at either end. (ensure there 

is no wiring/gas/water services directly 

behind the screws) refer to Dia:1.

2. Connect the mains in and load out wires 

according to Dia:2.

2. Re-connect mains supply, allow 30 seconds for the sensor to warm-up, and then per

form a walk-by in front of the sensor; lamp should turn on and stay on for 

approximately 10 seconds, and will go off if no further movement is detected.

Note:

Please refer to Data Sheet on the GreenBrook website -

www.greenbrook.co.uk for wiring sensor in parallel.

ODM201 Ins Aug 21_GU10  21/02/2022  15:13  Page 1