Protection function in each mode
Overload protection
Compressor discharge temperature protection
Communication mulfunction
Module protection
Other control
ON/OFF
The switch status is changed one time when pressing the ON/OFF key.
Mode function
Unit will choose and display the below mode when pressing mode key: AUTO, COOL DRY, FAN, HEAT, AUTO.
TEMP. setting button
Each time TEMP or TEMP button is pressed, the set temperature will be increased or decreased by 1 . Adjusting range is 16-30 .
In AUTO mode, this button does not function.
Auto key
If controller is turned on, it will be stopped when pressing this key. If controller is turned off, unit will run with
auto and swing is running whe
Timer control
The unit is turned on or off according to the timer set by the remote controller.
Sleep function
When the air conditioner is in Cool or Dry mode, after Sleep mode has been set properly, the preset Tset will
be increased by 1 after the sleep program has run for 1 hour, and Tset will be increased by another 1 after
2hours. Tset has been increased by 2 totally in two hours. Then the unit will run at this set temperature and the
set speed.
When the air conditioner is in HEAT mode, after Sleep mode has been set properly, the preset Tset will be
decreased by 1 after the sleep program has run for 1 hour, and Tset will be decreased by another 1 after
2hours. Tset has been increased by 2 totally in two hours. Then the unit will run at this set temperature and at
the set speed.
In Fan and Auto mode, the set temperature is fixed.
Indoor fan control
Use the remote controller to set the indoor fan running at High, Med or Low speed. At this time the fan will run
at high, medium or low speed. It can also be set to AUTO
Power supply for outdoor unit
Buzzer
The controller is powered on and detect the signal received, the buzzer will beep.
When module is in protection, the compressor will stop. It will resume running after stopping for 3mins.
During the period of module protection, there will display malfunction in indoor unit and total
unit will stop running.
There have communication mulfunction when unit don't receive the corrrect signal for 3 minutes, the unit will
stop running.
When the temp. is over the standard, then compressor stop running. When the discharge temp. resume the
original conditions and compressor has stop running for 3 minutes, the compressor will resume running.
When tube temp. is detected high, the compressor runs in limited frequency or slow-frequency. When the temp. is over standard, then
compressor stop running. In auto Heat or Heat mode, the indoor fan will blow for 60s and then stop. In other modes, the indoor fan will
run at the setting speed.
Tpreset
Tpreset
Tpreset
Setting temp. Tpreset
1hr.
2hrs.
2hrs. above
1hr.
2hrs.
2hrs. above
Tpreset
Tpreset
Tpreset
Setting temp. Tpreset
The method of power supply is outdoor power supply ( that is the power cable is directly conntected to outdoor unit),
the power supply of whole unit is not controlled by the controller.
Summary of Contents for Trendy Series
Page 1: ...1 115V R410A CANCEL Model Remarks Summary and features Trendy Series ...
Page 4: ...3 Window receiver Part name Indoor Unit Outdoor Unit ...
Page 6: ...UOverall and Installing Dimension of Outdoor Unit Unit mm Bolt Nut Wrench ...
Page 19: ...8 Trendy Series Exploded View and Components and Parts List Exploded View of Indoor Unit ...
Page 21: ...Trendy Series Exploded View of Components and Parts of Indoor Unit ...