Table 2 – RECEPTACLES AND FUSE TYPES
ELECTRICAL DATA
Nameplate Amps
AWG Wire Size †
7.0 to 12
14
12.1 to 16
12
16.1 to 24
10
Table 1 – SUGGESTED BRANCH CIRCUIT WIRE SIZES*
LEGEND
AWG – American Wire Gauge
* Single circuit main power wire
from electrical panel to unit.
AWG based on 240VAC Single
Phase, 100 ft. distance 1-way,
max. 5% allowable voltage drop.
GROUNDING
For safety and protection, the unit is grounded through the power cord plug or through separate
ground wire provided on hard wired units. Be sure that the branch circuit or general purpose
outlet is grounded.
VOLTAGE SUPPLY
Check voltage supply at outlet. For satisfactory results, the voltage range must always be within
the ranges found on the data information plate.
PROPER WALL RECEPTACLE OUTLET
The unit plug configuration must match the electrical wall outlet and be within reach of the
service cord. The standard cord – connected 265v units require an accessory electrical subbase.
Refer to Table 2 for proper receptacle and fuse type.
POWER CORD PROTECTION
The power cord for 208/230v units provide power cord safety protection. Unit power automatically
disconnects when unsafe conditions are detected. Power to the unit can be restored by pressing
the RESET button on LCDI plug head.
Upon completion of unit installation for 208/230V models, an operational check should be
performed using the TEST/RESET buttons on the plug head.
NOTE:
The 265v models do not incorporate this feature as they require use of the electrical
subbase receptacle accessory.
208/230
208/230
208/230
265
265
265
8
LEGEND
HACR-Heating,AirConditioning,Refrigeration
*Maybeusedfor15-ampapplications.