SYSTEM CONFIGURATION
DIP SWITCH CONFIGURATION
Freeze Guard
Setpoint Limit 1
Setpoint Limit 2
Fan CON/CYC for cooling
Fan CON/CYC for heating
Wall Thermostat Enable
Electric Heat Only (for heat pumps)
UP
DOWN
Table 4 – Dip Switch Functions
Fig. 18 – Dip Switches
Up
Electric Heat Only
Wall Thermostat Enable
Fan Continuous Run for Heating
Fan Cycle for Cooling
UP*UP
68-75°F
20-24°C
Freeze Guard Disable
UP*DOWN
63-80°F
18-28°C
DOWN*DOWN
61-86°F
16-30°C
(full range)
DOWN*UP
65-78°F
19-26°C
Down
Heat Pump
Control Panel Enable
Fan Cycle for Heat
Fan Continuous Run for Cooling
DOWN*UP
65-78°F
19-26°C
Freeze Guard Enable
Remarks
For Heat Pump Unit Only
Two configurations (5*6)
combine to select set point range.
When set point limit is set,
display always shows full range.
Default
DOWN
DOWN
DOWN
DOWN
DOWN
No.
1
2
3
4
5*6
7
16