16
Technical Information
Service Manual
2.3 Cooling and Heating Data Sheet in Rated Frequency
Cooling:
Rated cooling condition(°F)
(DB/WB)
Model
Pressure of gas pipe connecting
indoor and outdoor unit
Inlet and outlet pipe temperature of
heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor
Outdoor
PSIG
T1 (°F)
T2 (°F)
80/66.9
95/-
09K
130~142
in:46.4~51.8
out:51.8~57.2
in:167~181.4
out:98.6~118.4
Super High
High
12K
130~142
in:46.4~51.8
out:51.8~57.2
in:167~181.4
out:98.6~118.4
18K
130~142
in:46.4~51.8
out:51.8~57.2
in:167~181.4
out:98.6~118.4
24K
130~142
in:46.4~51.8
out:51.8~57.2
in:167~181.4
out:98.6~118.4
Capacity ratio(%)
Cooling
Heating
Capacity ratio(
%)
Outdoor temp.(°F)
Outdoor temp.(°F)
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
5 17 23 32 41 50 57 67 75 86 95 104 113 122
-13 -5 0 5 10 17 20
19.4
24 32 41 43 47 53 59 64 70 75.2
Conditions
Indoor:DB80°F/WB66.9°F
Outdoor:DB95°F
Indoor air flow:Super High
Pipe length:24.6ft
Conditions
Indoor: DB70°F
Outdoor: DB19.94°F/WB19.04°F
Indoor air flow: Super High
Pipe length: 24.6 ft
Cooling operation ambient temperature range is 0.4
o
F~122
o
F.
Hheating operation ambient temperature range is 19.4
o
F~75.2
o
F.
24K:
Cooling operation ambient temperature range is 0
o
F~118
o
F.
Heating operation ambient temperature range is -13
o
F~75
o
F.
18K:
0
20
40
60
80
100
120
140
0
5
17 23 32 41 50 57 67 75 86 95 104 110 118
Capacity ratio(%)
Cooling
Outdoor temp.(°F)
Conditions
Indoor:DB80°F/WB66.9°F
Outdoor:DB95°F
Indoor air flow:Super High
Pipe length:24.6ft
0
20
40
60
80
100
120
-13
5
14
20
32
36
40
45
48
50
59
65
70
75
Heating
Capacity ratio(
%)
Outdoor temp.(°F)
Conditions
Indoor: DB70°F
Outdoor: DB19.94°F/WB19.04°F
Indoor air flow: Super High
Pipe length: 24.6 ft
Summary of Contents for N00600
Page 1: ...Service Manual Change for life GREE ELECTRIC APPLIANCES INC OF ZHUHAI 4LIV09 24 Models ...
Page 93: ...90 Installation and Maintenance Service Manual INTENTIONALLY BLANK ...
Page 95: ...92 Installation and Maintenance Service Manual INTENTIONALLY BLANK ...
Page 96: ...93 Installation and Maintenance Service Manual INTENTIONALLY BLANK ...