PANEL CONTROL 

CAUTIONS:

 

If  the  unit  is  turned  off  in  cool  /dry/  heat  mode  and  restarted 

immediately , then it will wait at least 3minutes before running again.

 

 

1. Buttons 

 

Timer: press this button to set the timer 

  Swing: press this button to make the vertical louver swing automatically. 

Press once again, the swing will stop. 

  Speed: press this button for 5 seconds to select high, middle or low fan 

Speed. 

Up/down: press up or down button to set temperature or adjust the time in 
   

   

  Timer mode. Press both buttons to vary from Celsius to Fahrenheit. 

  Mode: press this button to select cool, heat, dry or fan mode (heat mode 

only in YPC-H models). 

  Econ: press this button to a set energy saving mode (only in heat and cool 

mode). This set temperature is 27

  in cool mode and 23

  in heat 

mode . The fan speed is low. These data can’t be changed. The LED 
display will flash    or 

  accordingly. Press again to cancel it when   

  or 

  is flashing.   

  Power: press this button to turn on/off the unit. 

2. LED display   

             

Timer indicator 

      Dry, cool, fan and heat mode indicator (no 

  in YPC-C models) 

            High, middle and low fan speed indicator 

            Water Full indicator 

            Water Injection indicator 

            IR receiver window 

            Indicate the time and temperature. Display EX (X=2,3,5) when 

there is something wrong (refer to Self diagnosis function). 
Display E4 when coil is defrosted. 

          Celsius degree and Fahrenheit degree indicator. 

Summary of Contents for KY-26

Page 1: ...Y 32 KYD 32 KY 44 KYD 44 PORTABLE AIR CONDITIONER Thank you for selecting super quality air conditioner Please be sure to read this manual carefully before using it Any question please contact the pro...

Page 2: ...1 IMPORTANT SAFEGUARDS 2 FEATURES AND PARTS LIST 4 PANEL CONTROL 5 REMOTE CONTROL 6 OPERATION METHODS 7 INSTALLATION 8 WATER DRAINGE METHODS 10 MAINTENANCE 11 TROUBLE SHOOTING 12 INSTALLATION ACCESSO...

Page 3: ...g to instructions When the power cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Do not use your appliance with...

Page 4: ...of the day Keep the filters clean Under normal conditions the filters should be cleaned approximately every 30 days Since the filters remove airborne particles more frequent cleaning maybe necessary d...

Page 5: ...gy saving and environment protect Low noise and strong wind Unique economic function Auto swing makes wind blow from left to right automatically Three minute restart delay to protect compressor Parts...

Page 6: ...ol heat dry or fan mode heat mode only in YPC H models Econ press this button to a set energy saving mode only in heat and cool mode This set temperature is 27 in cool mode and 23 in heat mode The fan...

Page 7: ...Press this button to choose Fan mode Up Press Up or Down button to set temperature Down or adjust the time in Timer mode High Press this button to select high fan speed Med Press this button to select...

Page 8: ...tically Cooling Heating and Dehumidifying operation 1 Cooling Heating operation Press Mode button or to choose Cool heat mode Press Up or Down button or to set a proper room temperature The range is 1...

Page 9: ...is between 600cm to 1700cm or 1800cm adapters included We suggest using the minimum length of the air exhaust dust That can save energy for you This length has been designed especially according to th...

Page 10: ...9 4 Mounting illustrations 1 mounting in the wall 2 correct bending 3 wrong bending...

Page 11: ...evel or drained by hand When the alarm stops and after three minutes restart delay the unit will work normally You can drain the water out with a drain pipe It is included in the accessory But first y...

Page 12: ...Rinse the filter and dry it in a shaded place 3 Push the air filter back into the original position End of season 1 Pull out the plug from the drain mouth and remove the water from the drain pan You c...

Page 13: ...able fan speed Too noisy and vibration It is the inner liquid refrigerant flowing inside Is it inclined It is normal Place it in a flat place The unit starts and stops frequently Is the voltage normal...

Page 14: ...ch from 7000BTU 8000BTU 9000BTU 14 36cm up to 59 150cm 12000BTU 14000BTU 15000BTU 15 38cm up to 59 150cm Window exhaust adapter flat mouth 1pc Adjustable window slider kit 2 set From 35 3 8 90cm up to...

Page 15: ...1 Fuse Parameter Type FSD Voltage 250V Current 3 15A 2 Wiring Diagram Fig 16 Disposal Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment...

Reviews: