background image

36

9.2 

1

Left Decoration Plate

导板挤塑条左装饰板

1

2

Shaft of Louver I

导风板转轴

I

2

3

Swing Louver Fixer

扫风叶片安装板

1

4

Louver Support

导风板支架

3

5

Louver Fixer

导风板固定架

2

6

Louver

导风板

1

7

Shaft of Louver II

导风板转轴

II

2

8

Right Decoration Plate

导板挤塑条右装饰板

1

9

Left Swing Motor Fixer

扫风电机左安装板

1

10

Front Panel

面板组件

1

11

Display Box

电路板安装盒

1

12

Display Board

显示板

 6152BJ/6151BJ              

1

13

Buttons Panel

按键面板组件

1

14

Right Swing Motor Fixer

扫风电机右安装板

1

15

Step Motor MP35CA

步进电机

(

导风

) MP35CA

2

16

Motor Clamp

扫风电机压板

4

17

Water Tray

接水盘

1

18

Auxiliary Water Tray

辅助接水盘

1

19

Pipe Clip

管箍

1

20

Drainage Pipe

排水管组件

1

21

Handle

提手

4

22

Foam of Right Side Plate

右侧板泡沫

1

23

Right Fixing Palte

右安装板

1

24

Support of Motor Bearing

电机轴承座

2

25

Fixer of Motor Support

电机支架支撑板

1

26

Right Decoration Panel

右装饰板

1

27

Pipe Clamp

蒸发器出管压板

1

28

Electric Box

电器盒组件

                

1

29

Wire Base

压线座

1

30

Wire Clamp

压线板

1

31

Terminal Board RS9413G

接线板

 RS9413G                    

1

32

Fuse 5A 250VAC

保险管

5A 250VAC VDE

1

33

Main PCB

主板

6152J/6151J  

1

34

Ring of Bearing

轴承胶圈

2

No

Description

KFR-70D/NA1

24212020

24222016

10512404

26112026  

26112417

10512025

01332410

24253001

24253002

01072424  

20102138

30546106

01272413  

01272411

70812001

42010178

10512026

26112421

26152007

01532414

26232001

12312408

01332404

01792409  

26112033

05235433

20162004  

26152008  

15212402

01792408

30036052

46010013

76512404  

46010013

Qty

KF-70D/NA1

26112417

10512025

01332410

24212020

24222016

10512404

10512026

26112421

26152007

01532414

20102138

30546105

20162004  

26152008  

15212402

26112026  

01272411

01272413  

70812001

05235433

26232001

01403242  

12312408

01332404

01792408

01792409  

26112033

01072424  

30036051  

76512404  

01403242  

24253001

24253002

42010178

Part Code

Spare parts lists of indoor unit

Summary of Contents for KFR-70DW/NA1

Page 1: ...Service people and engineers of Gree s customers and distributors would find it a very handy source of technical information of our products Technical Support Group Mar 2004 Contents Summary Technical...

Page 2: ...1 KF 70DW NA1 1Ph 230V 50Hz R407C KFR 70DW NA1 Summary Model Note...

Page 3: ...Swing Motor MP35CA Input Power of Motor W 4 Fuse A controllor5A transformer0 2A Working Capacitor uF 3 Noise dB A 48 Dimension W D H mm 1300X188X600 Dimension of Package W D H mm 1414x248x724 Indoor u...

Page 4: ...mm 1100x450x920 Net Weight Gross Weight kg 75 87 Refrigerant Charge kg R407C 2 4 Length m 5 Liquid Pipe mm 9 52 3 8 Outer Diameter Gas Pipe mm 16 5 8 Height m 5 Connecting Pipe Max Distance Length m...

Page 5: ...Area m2 1 042X 0 19 Swing Motor MP35CA Input Power of Motor W 4 Fuse A Controllor5A transformer0 2A Working Capacitor uF 3 Noise dB A 47 Dimension W D H mm 1300x188x600 Dimension of Package W D H mm...

Page 6: ...mm 1100x450x920 Net Weight Gross Weight kg 75 87 Refrigerant Charge kg R407C 2 5 Length m 5 Liquid Pipe mm 9 52 3 8 Outer Diameter Gas Pipe mm 16 5 8 Height m 5 Connecting Pipe Max Distance Length m...

Page 7: ...3 7 Namesofspareparts Indoor unit Left decoration plate Airguidelouver LEDboard Right decoration plate Frontgrill Wrappingtape Connectionpipe Valve Airout Airin Outdoorunit Wirelessremotecontrol...

Page 8: ...100cm 30cm 60cm 60cm 150cm 8 Outlinesandinstallationdimension Outlinesanddimensionsofindoorunit or more or more or more ormore ormore...

Page 9: ...50 572 378 412 340 70 65 106 9 Outlines and dimensions of outdoor unit Unit Handle Gas pipe Wire hole Liquid pipe Front grill More than More than Morethan Airoutlet Floor More than More than More than...

Page 10: ...refrigerant gas into outdoor heat exchanger With the help of axial flow fan the gas transfers its latent heat into outdoor air and becomes high pressure refrigerant liquid The liquid is throttled by...

Page 11: ...11 KFR 70DW NA1 KF 70DW NA1 Circuit diagram The circuit diagram are subject to change please refer to the ones on the machine...

Page 12: ...oor fan motor run Indoor fanmotor and swing motor run at the setting fan speed and setting When Tamb Tset 1 compressor outdoor fan motor stop running Indoor fan runs at set fan speed When Tset 1 T amb...

Page 13: ...it is turned off or swtich to othermode after compressor stopped for 2min the 4 way valve is powered off Conditions for anti cool wind When compressor start to run in HEAT mode the indoor fan motor do...

Page 14: ...s 24 When Tamb 20 it will run in HEAT mode inner setting temp is 20 Tamb 24 quit HEAT mode If it is cooling only type unit when Tamb 20 it will run in FAN mode inner setting temp is 24 When each mode...

Page 15: ...compressor stopped detected low pressure switch tripped off the unit stop and E3 displayed that cannot resume automatically need to press ON OFF to turn off the unit then repress ON OFF button can re...

Page 16: ...rror codes E1 Compressor high pressure protection E2 Indoor anti freezing protection E3 Compressor low pressure protection E4 Air exhaust pipe high temp protection E5 Low pressure protection Functions...

Page 17: ...the indicator flash When power suply indicator is powered on it will light when powered off it will extinguish When it is indoor anti freezing protection compressor high pressure protection low press...

Page 18: ...s very hot SWING button When it is pressed the louvers start to rotate automatically and stop when repressed FAN button Press this button to change the fan speed of AUTOFAN COOL mode DRY mode FAN mode...

Page 19: ...to this air conditioner will not be described below Liquid crystal displayer It shows all set contents SLEEP button PressthisbuttontosetSLEEP operationandstopwhenrepressed TIMER OFF button At stoppin...

Page 20: ...pera ture Press MODE button to select When pluged in press 1 0 button the unit will start to run Microcomputer will accord to the room sensor detected the temp and setting temp differences to start th...

Page 21: ...indoor fan motor stop running water valve is turned off heat operation is stopped The setting range is Press SWING button the louver guide will automatically swing when repressed it once more it will...

Page 22: ...fan speed is unavailable select the if the When room sensor detected the temp is lower than setting temp 2 or more the water valve indoor fan motor stop running When room sensor detected the temp is b...

Page 23: ...O mode the standard cooling setting temp is 25 the standard heating setting temp is 20 When plug in press 1 0 unit will start to run 1 Press MODE button to select AUTO mode Microcomputer will achieve...

Page 24: ...ER operation mode At stopping can set timer on each time to press TIMER ON the time will be increased 0 5h circulates as below At running can set timer off each time to press TIMER OFF the time will b...

Page 25: ...ature Press MODE button to select modes When pluged in press 1 0 the unit will start to run In cool and dry modes set the sleep operation and run for 1 hour later the setting temp will be increased 1...

Page 26: ...tteries Cover Never mix new and used or diff erent types of two batteries to insert Take out the batteries when the wireless remote control is not in use to avoid the the liquid damage it The operatio...

Page 27: ...photo by screwdriver then take out the left right decoration plates along the direction of arrow Disassemble electric box assy a Screw off 2pcs bolts with screwdriver as shown in Fig 8 3 and take off...

Page 28: ...assy To screw off 3pcs bolts in the photoes can disassemble the water tray assy Disassemble swing louver and holder assy Firstly to screw off 2pcs bolts at two ends of the swing louver holder assy by...

Page 29: ...Right side plate foam sub assy Left side plate foam sub assy According to the direction to take out the left right sides plates foam sub assy Disassemble motor assy a Pressing the clasp position wher...

Page 30: ...Disassemble the motor holder supporting plate Using the screwdriver to screw off the bolts in the motor holder rear side plate assy and supporting plate Disassemble the left and right plates Using the...

Page 31: ...p cover To screw off the bolts around the top cover then lift it upward can take off the top cover As shown in Fig Disassemble the front side plate To screw off the bolts around the top cover then dow...

Page 32: ...rear side plate assy Screw off 5pcs bolt of the rear side plate and 2pcs bolt of the rear grill can disass emble the rear side plate assy As shown in Fig Disassemble the gas valve and liquid valve To...

Page 33: ...oint Disassemble the outdoor unit motor Toscrewoffthefixingboltofmotorandmotor support and pull out the connection wire of the motor can take off the motor Disassemble four way valve only the cooling...

Page 34: ...ser gate then can dis assemble the capillary make sure that do not let any weld ing dregs to block the capillary As show in right fig Capillary assy Fig Fig Bottom bolts Disassemble the compressor Fir...

Page 35: ...9 35 Explosive view of indoor unit spare parts Explosiveviewandsparepartslists...

Page 36: ...ase 1 30 Wire Clamp 1 31 Terminal Board RS9413G RS9413G 1 32 Fuse 5A 250VAC 5A 250VAC VDE 1 33 Main PCB 6152J 6151J 1 34 Ring of Bearing 2 No Description KFR 70D NA1 24212020 24222016 10512404 2611202...

Page 37: ...Foam 1 64 Bearing Fixing Plate 1 65 Rear Side Plate of Air Outlet 1 66 Connecting Lever 3 67 Connecting Lever 2 68 Swing Louver 22 10582009 10512028 01332405 12312405 01302405 10582008 01332407 39000...

Page 38: ...38 Explosive view of outdoor unit spare parts...

Page 39: ...0H5B C RN220H5B 1 35 Overload Protector 1 36 Compressor Gasket 3 37 Metal Base 1 38 Isolation Sheet Assy 1 39 Front Plate 1 07255251 03003431 430004031 01303709 26235252 75013118 76710210 06123401 071...

Page 40: ...loth is wet please dry it after cleaned Warning Never use the benzene gasoline or something is hard to clean Never use the hot water 40 above for cleaning in order to avoid some spare part or part def...

Page 41: ...c diagram to check the cir cuit and correctly connect The fuse of controller is melt Replace the fuse of controller Both indoor unit and outdoor unit can not start Is the wire connection current plate...

Page 42: ...broken or damaged Wrong wiring According to circuit diagram to connect wire c orrectly The installation place of indoor unit is not suitable Indoor unit filter blocked Outdoor unit heat exchanger bloc...

Page 43: ...the loosen bolts Outdoor pipelines collide each other To deleave the collided pipelines Indoor metal sheets collide each other 2 Stickthe dumping cushion ts between metal shee 1 Tighten the connect b...