17
7.5.1
7.5.2
7.5.3
7.6
7.7
SWING Control
In FAN mode:
The auto fan speed is as the same as the cool mode.
In COOL mode:
If Tamb
≤
Tset, that is low speed
If Tset
<
Tamb
≤
Tset+3
℃
, is medium speed
If Tamb
>
T set+3
℃
, is high speed
If Tamb
≥
Tset, is low speed
I
f Tset-3
℃≤
Tamb
<
Tset, is medium speed
If Tamb
<
Tset-3
℃
, is high speed
In HEAT mode:
The auto fan speed control of the fan motor
The buzzer control
When controller is powered on or received the signals, the buzzer will sound.
Use SWING button to start or stop the control, only when indoor fan motor is running the SWING operation is available.
Indicators:
defrosting operations, the indicator flash.
When power suply indicator is powered on, it will light, when powered off, it will extinguish. When it is indoor
anti-freezing protection, compressor high pressure protection, low pressure protection as well as
The COOL indicator is lighting in COOL mode, DRY mode, Auto COOL, Auto DRY, in the other modes will extinguish.
The HEAT indicator is lighting in HEAT mode, and Auto HEAT mode, it will extinguish in other modes.
Memory function:
Memory contents: when MODE, SWING, TEMP. Setting, FAN Setting, TIMER Setting (When the time hasn't
arrived, and it powered off, the time will be recalculated; if the time had arrived and it is powered off, when
powered on, it will run at the mode which is the time arrived.)
After powered off, when powered on, the unit can automatically start up and run at the memory contents.