17
7.8 COOL mode operation
●
According to room temperature, set temperature and the change rate of room temperature, microcomputer of the remote
controller will be able to control the output cooling capacity of the outdoor compressor.
●
If room temperature is equal to or slightly higher than the set temperature, the compressor will run. If room temperature is 2.5
℃
higher than the set temperature, the compressor will run at its max. capacity. If the difference between room temperature
and set temperature is between 1
℃
and 2.5
℃
, the compressor will stop, the outdoor fan will stop after 30sec and the indoor
fan will run at low speed.
●
If the fan is set at AUTO mode, microcomputer of the remote controller can control the speed of indoor fan via the output
power of outdoor compressor.
●
In this mode, the temperature setting range is 16
℃~
30
℃
.
●
At this time, the LCD appears green.
4. Press the FAN button to
set fan speed.
3. Press the SWING button
and the guide louver starts
to swing automatically and
stops when it is pressed
again.
5. Press the TEMP
button to set the desired
temperature.
2. Press the MODE
button to select “ ”
mode.
1. After power-on, press the “1/0”
button to set the air conditioner
running.
Summary of Contents for KFR-32GW/NJ1F
Page 2: ...1 1 Summary and features Models Remark...
Page 3: ...3 2 Specifications and technical parameters...
Page 4: ...4...
Page 7: ...7 4 2 Outline and installation dimension of outdoor unit Unit mm Above 60cm Bolt Nut Spanner...
Page 33: ...33 9 Explosive view and parts and components list 9 Explosive view of indoor unit...
Page 35: ...35 The above date is subject to change without further notice...
Page 36: ...36 9 3 Explosive view of outdoor unit...
Page 38: ...38 The above data is subject to change without further notice Built in Built in...