1.Plug in, press ON/OFF button,
and then air conditioner is turned
3.Press SWING button, the
louvers start to rotate
automatically and stop when
repressed.
4.Press FAN button, set fan speed.
5.Press TEMP. button, set
suitable SET TEMP.
2.Press MODE button, set
operation mode.
-
8
-
on.
HEAT mode operation procedure
According to the differences between room temp. and set temp. and
the rising rate of room temp. microcomputer can control output power
If room temp. is lower than set temp. adds 2
℃,
the compressor starts.
If the value of room temp. subtracted set temp. is smaller than 5
℃
bu
t
greater than 2
℃,
th
e compressor keeps in fuzzy operation between
maximum power and minimum power according to the difference in
temperature. If room temp. is 5
℃
h
igher than set temp., compressor will
If fan speed is set at AUTO mode microcomputer can control fan speed
of the indoor fan
Set temp. should
stop, outdoor fan motor will stop after30 seconds, indoor fan motor will
stop after 60 seconds.
of the compressor, that is, the heating capacity.
motor according to the
output power of the compressor.
be in range of 16
℃
to
30
℃
.