92
Installation and Maintenance
Service Manual
Step
P
s
rocedure
19. Remove electronic expansion valve assy
20. Remove condenser assy
electronic expansion valve assy
condenser assy
Unsolder the welding joint connecting the electronic
expansion valve sub-assy with the gas collection pipe,
and then remove the electronic expansion valve assy.
(Note: when unsoldering, wrap the gas valve with a wet
cloth completely to avoid damage to the valve caused
by high temperature).
Remove the screws connecting the condenser
assy and the chassis assy, and then remove the
condenser assy.