Installation and Maintenance
Service Manual
Procedure
Step
a
b
d
c
Screws
Connection pipe
7. Remove evaporator assy
At the back of the unit, Loosen the
clasp,connection pipe clamp and then
remove the connection pipe clamp.
First remove the left side of evaporator from
the groove of bottom shell and then remove
the right side from the clasp on the bottom
shell.
Remove 3 screws fixing evaporator assy.
Adjust the position of connection pipe
on evaporator slightly and then lift the
evaporator upwards to remove it.
Connection pipe clamp
Evaporator assy
Clasp
Groove
Clasp
Rear Case assy