71
Installation and Maintenance
Service Manual
Step
Procedure
11.Electric box assy
12.Remove connection pipe clamp
13.Remove evaporator assy
14.Remove stepping motor
Screw
Screw
Electric box assy
Connection pipe clamp
Evaporator assy
Connection pipe
Remove the screw fixing electric box
assy and then remove the electric box
assy.
At the back of the unit, remove the
screw fixing connection pipe clamp
and then remove the connection pipe
clamp.
Remove 3 screws fixing evaporator assy.
Adjust the position of connection pipe
on evaporator slightly and then lift the
evaporator upwards to remove it.
Remove the screw fixing step motor and
then remove the step motor.
Screws
Screws
Screws
Step motor