background image

I FEEL

NOTE

CLOCK

SLEEP

Press this button, can select Sleep 1 (     1),

Sleep 2 (      2), Sleep 3 (      3) and cancel the 

Sleep, circulate between these, after electrified, 

Sleep Cancel is defaulted.

16

 

Clock time adopts 24-hour mode.

 

The interval between two operations can

'

t exceed 5s. 

Otherwise, remote controller will quit setting status. 
Operation for TIMER ON/TIMER OFF is the same.

Sleep 1 is Sleep mode 1, in Cool modes; sleep

status after run for one hour, the main unit setting 

temperature will increase 1 , two hours, setting 

temperature increased 2

, then the unit will run at

this setting temperature; In Heat mode: sleep 

Sleep 2 is sleep mode 2, that is air conditioner

status after run for one hour, the setting tempera- 

ture will decrease 1 , two hours, setting tempera-

ture will decrease 2 , then the unit will run at this 

setting temperature.

will run according to the presetting a group of 

sleep temperature curve.

Sleep 3-the sleep curve setting under Sleep

Press this button to set clock time. "      " icon on 

remote  controller  will  blink.  Press  " "  or  " " 

button within 5s to set clock time. Each pressing of 

" "  or  " "  button,  clock  time  will  increas  e  or 

decrease  1  min.  If  hold  " "  or  " "  button  ,  2s 

later,  time  will  change  quickly.  Release  this  button 

when  reaching  your  required  time.  Press  "CLOCK" 

button to confirm the time. "     " icon stops blink-

ing.

NOTE

Under on and off status, you can set T-OFF or T-ON 

 

simultaneously. 

Before setting T-ON or T-OFF, please adjust the 

clock time.

After starting up T-ON or T-OFF,set the constant 

circulating valid.

After that, air conditioner will be turned on or turned 

off according to setting time. ON/OFF button has no 

effect on setting. If you don’ t need this function, 

please use remote controller to cancel it.

mode by DIY could be inquired:

Sleep3- the sleep curve setting under Sleep

mode by DIY;

(1) Under Sleep 3 mode, press “TURBO” button for a

long time, remote controller enters into user indi-

viduation sleep setting status, at this time, the time 

of remote controller will display “1hour”, the setting 

temperature “88” will display the corresponding 

temperature of last setting sleep curve and blink 

(The first entering will display according to the 

initial curve setting value of original factory);

(2) Adjust “

” and “

” button, could change the

corresponding setting temperature, after adjusted, 

press “TURBO” button for confirmation;

(3) At this time, 1hour will be automatically 

increased at the timer position on the remote con-

trol, (that are "2hours" or "3hours" or "8hours"), the 

place of setting temperature "88" will display the 

corresponding temperature of last setting sleep 

curve and blink;

(4) Repeat the above step (2)~(3) operation, until 

8 hours temperature setting finished, sleep,curve 

setting finished, at this time, the remote controller 

will resume the original timer display; temperature 

display will resume to original setting temperature.

The user could accord to sleep curve setting 

method to inquire the presetting sleep curve, enter 

into user individuation sleep setting status, but do 

not change the temperature, press "TURBO" button

directly for confirmation. Note: In the above preset-

ting or enquiry procedure, if continuously within 

10s, there is no button pressed, the sleep curve 

setting within 10s, there is no button pressed, the 

sleep curve setting status will be automatically quit 

and resume to display the original displaying. In 

the presetting or enquiry procedure, press 

"ON/OFF" button, "MODE" button, "SLEEP" button,

the sleep curve setting or enquiry status will quit 

similarly.

Press this button to start I FEEL function and "      " 

will be displayed on the remote controller. After this

function is set, the remote controller will send the 

detected ambient temperature to the controller 

and the unit will automatically adjust the indoor te-

mperature according to the detected temperatu

 

re. 

Press this button again to cancel I FEEL function 

and "      " will disappear. 

Please put the remote controller near user when

 

 this

function is set. Do not put the remote contro

 

ller 

near the object of high temperature or low temper-

ature in order to avoid detecting inaccurate am

 

bie-

nt temperature.When I FEEL function is turned on, 

the remote controller should be put within the a

 

rea 

where indoor unit can receive the signal sent by

 

 

 the 

remote controller. 

Summary of Contents for GWH07AGA-K6DNA1A/I

Page 1: ...on and introduction of remote controller 20 Configuration of connection pipe Specialist s Manual 22 NOTE Actual product may be different from graphics please refer to actual products Thank you for cho...

Page 2: ...9AGB K6DNA1B I GWH09AGC K6DNA1F I GWH12AGB K6DNA1A I GWH12AGB K6DNA4A I GWH12AGC K6DNA1A I GWH12AGC K6DNA1F I GWH18AGD K6DNA1A I GWH18AGD K6DNA1D I GWH18AGD K6DNA1E I GWH18AGD K6DNA4A I GWH24AGD K6DNA...

Page 3: ...reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information u...

Page 4: ...aware that refrigerants may not contain an odour Read specialist s manual All the work men who are engaging in the refrig eration system should bear the valid certification awarded by the authoritati...

Page 5: ...erant If you should cut or weld the refrigerant system pipes in the process of maintaining please foll ow the steps as below c Vacuuming d e Cutting or welding Clean it with N2 gas f Carry back to the...

Page 6: ...ir conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The groundi...

Page 7: ...must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation For the air conditioner with out plug a circuit breaker...

Page 8: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Page 9: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 10: ...ystem pre ssure rise or compressor rupture resulting in injury Measuring tape spanner Inner hexagon When installing or moving this unit do not charge the refrigerant which is not comply with that on t...

Page 11: ...e requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket 5 B...

Page 12: ...es when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 7 The pipe can be led ou...

Page 13: ...ross hole at the back of indoor unit and then pull it out from the front side panel screw wiring cover outlet pipe drain hose All wires of indoor unit and outdoor unit should be If the length of power...

Page 14: ...on pipe drain hose with the band drain hose band indoor power cord Put the bound pipes in the wall pipe and then Bind up the connection pipe power cord and NOTICE make them pass through the wall hole...

Page 15: ...on 1 2 3 Clean and maintenance 2 WARNING WARNING Please contact qualified professionals for service Error Code Error code F2 E8 Troubleshooting C5 F0 F1 U8 H6 H3 E1 E5 E6 Notice for recovery 1 Clean s...

Page 16: ...ck the batteries If the power of batter s e i o l is too w please rep lace them Under heating mode indoor temperature is reached to set temp erature Power failure Is plug loose In order to prevent blo...

Page 17: ...turn off the air conditioner When the air conditioner is turned on it will operate under auto mode Display Temp indicator Power indicator This is the general introduction and the color of indicator i...

Page 18: ...t Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Left right swing Up down swing Child lock Dry mode Fan mode Heat mode Temp I feel Set fan speed display ty...

Page 19: ...multifunction For the functions which the model doesn t have if press the corresponding button on the remote controller the unit will keep the original running status After putting through the power...

Page 20: ...ngle When selecting air condition er is blowing fan at xed position Horizontal louver will stop at the xed position Press or button once increase or decr ease set temperature 1 F Holding or button 2s...

Page 21: ...display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of original factory 2 Adjust and button could...

Page 22: ...usted Under 8 heating function set temperature can t be adjusted Press TURBO button and the remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If...

Page 23: ...f the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evaporator the unit will perform fast cooling or fast heating There may be...

Page 24: ...function or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve...

Page 25: ...m and 8m the min length of con nection pipe is 3m Max length of connection pipe is shown as below 4 1 2 The calculation method of additional refrigerant oil and refrigerant charging amount after prolo...

Page 26: ...fferent according to the diameter please refer to the sheet below DB WB C any blemish expand the port again according to the steps above Outdoor side DB WB C Maximum GWH12AGC K6DNA1F I LC GWH09AGC K6D...

Page 27: ...al ed or intrinsically safe Presence of fire extinguisher If any hot work is to be conducted on the refrigera tion equipment or any associated parts appropriate Ventilated area Ensure that the area is...

Page 28: ...and being used correctly the recovery process is supervised at all times by a competent person d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that refrige...

Page 29: ...refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not i...

Page 30: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Tel 86 756 8522218 Fax 86 756 8669426 E mail global cn gree com Web www gree com Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 600005062912...