55
Installation and Maintenance
Service Manual
Connecting method for terminals
There is a buckle in this position,
when pulling out the terminal,
please press the buckle and then
pull out the terminal verti
cally.
Directly pull the white sleeve to pull
put the terminal. Do not drag the pow
-
er cord, otherwise the terminal may
be damaged.
Notes:
1. Please hold the sleeve when pulling or inserting the terminals. It is not allowed to directly drag the wire, otherwise the wire
and terminal may be loose or disconnected.
2. Do not swing the connecting slice of terminal when pulling out the terminal, otherwise the terminal may be loose or discon
-
nected.
3. The terminal is with buckle, when it is correctly connected, you will hear a click. When it is correctly connected, the terminal
and connecting slice will be automatically matched, do not drag the wire to check if they are firmly connected.
Make sure that this buckle is well connected,
otherwise it may cause malfunction of com
-
pressor or large resistance of electric wire
and burnout of terminal.
Please first press this buckle and then pull
along the direction of wire to pull
out
the
terminal.
5. Checking and maintenance method for major parts
5.1 Rectifier bridge
Appearance and inner diagram (the following silkscreen is only for reference. It depends on different models and
manufacturers):