14
Multi VRF Indoor
Unit Service Manual
PRODUCT
3.1.2 One-way Cassette Type
Model
GMV-R22Td/Na-K
GMV-R28Td/Na-K
GMV-R36Td/Na-K
Product Code
CM502N0010
CM502N0030
CM502N0050
Model
GMVL-R22Td/Na-K
GMVL-R28Td/Na-K
GMVL-R36Td/Na-K
Product Code
CM502N0020
CM502N0040
CM502N0060
Cooling Capacity
kW
2.20
2.80
3.60
kBtu/h
7.51
9.55
12.28
Heating Capacity
kW
2.50
3.20
4.00
kBtu/h
8.53
10.92
13.65
Air Flow Rate
m
3
/h
450
500
500
CFM
265
294
294
ESP(standard/max./range)
Pa
0
0
0
Sound Pressure Level (H/M/L)
dB(A)
45 /43 /41
45 /43 /41
45 /43 /41
Power Supply
V/Hz/Ph
220-240/50/1
220-240/50/1
220-240/50/1
Fan Motor
Output
kW
0.02
0.02
0.02
Running Current
A
0.19
0.19
0.19
Connecting
Pipes
Gas Pipe
mm
Φ9.52
Φ9.52
Φ12.7
inch
Φ3/8
Φ3/8
Φ1/2
Liquid Pipe
mm
Φ6.35
Φ6.35
Φ6.35
inch
Φ1/4
Φ1/4
Φ1/4
Connection Method
Flare Connection
Flare Connection
Flare Connection
Drain Pipes (External Dia.×Thickness)
mm
30×1.5
30×1.5
30×1.5
Unit Dimensions (W×D×H)
mm
920 ×360 ×185
920 ×360 ×185
920 ×360 ×185
Package Dimensions (W×D×H)
mm
1290 ×465 ×270
1290 ×465 ×270
1290 ×465 ×270
Net Weight
kg
16.0
16.0
16.0
Gross Weight
kg
25.0
25.0
25.0
Loading Quantity ( 20’ Container )
unit
101
101
101
Loading Quantity ( 40’ Container )
unit
216
216
216
Loading Quantity
( 40’ High Cube Container )
unit
251
251
251
Notes:
① .
The above performance parameter is measured according to the standard of GB/T 18837-2002.
② .
Always see the nameplate for the speciied parameters.
③ .
The model with GMVL code is cooling only unit; while the model with GMV code is heat pump unit; the
cooling only units dose not have any parameters of performing heating.
④ .
Above parameters are tested under the condition:high fan speed
Cooling : Indoor air temperature 27°C DB/19°C WB;
Heating : Indoor air temperature 20°C DB/15°C WB.
⑤ .
The noise test is conducted in the semi-anechoic or anechoic chamber, and the loor of the former is a
relecting surface.
Location of microphone:
1
.4
m
Microphone
Indoor Side
Cassette
Summary of Contents for GMV-R series
Page 1: ...T1 R410A 50Hz GC201110 I...
Page 4: ...Multi VRF Indoor Unit Service Manual 1 PRODUCT PRODUCT...
Page 40: ...Multi VRF Indoor Unit Service Manual 37 CONTROL CONTROL...
Page 42: ...Multi VRF Indoor Unit Service Manual 39 CONTROL 1 1 Cooling Operation...
Page 43: ...40 Multi VRF Indoor Unit Service Manual CONTROL 1 2 Heating Operation...
Page 44: ...Multi VRF Indoor Unit Service Manual 41 CONTROL 1 3 Fan Operation 1 4 Dry Operation...
Page 54: ...Multi VRF Indoor Unit Service Manual 51 INSTALLATION...
Page 80: ...Multi VRF Indoor Unit Service Manual 77 MAINTENANCE...
Page 134: ...Multi VRF Indoor Unit Service Manual 131 Exploded View of GMV R56P NaB K GMV R71P NaB K...
Page 141: ...138 Multi VRF Indoor Unit Service Manual Exploded View of GMV R56PS NaB K GMV R71PS NaB K...
Page 145: ...142 Multi VRF Indoor Unit Service Manual Exploded View of GMV R224P NaB M...
Page 147: ...144 Multi VRF Indoor Unit Service Manual Exploded View of GMV R280P NaB M...
Page 155: ...152 Multi VRF Indoor Unit Service Manual Exploded View of GMV L R36G NaB K GMV L R45G NaB K...
Page 157: ...154 Multi VRF Indoor Unit Service Manual Exploded View of GMV L R50G NaB K GMV L R56G NaB K...
Page 159: ...156 Multi VRF Indoor Unit Service Manual Exploded View of GMV L R22G NaC K GMV L R28G NaC K...
Page 161: ...158 Multi VRF Indoor Unit Service Manual Exploded View of GMV L R36G NaC K GMV L R45G NaC K...
Page 163: ...160 Multi VRF Indoor Unit Service Manual Exploded View ofGMV L R71G Na K GMV L R80G Na K...
Page 165: ...162 Multi VRF Indoor Unit Service Manual Exploded View of GMV L R22G NaG K GMV L R28G NaG K...
Page 173: ...170 Multi VRF Indoor Unit Service Manual 2 Exploded View of GMV R71Zd NaB K GMV R90Zd NaB K...
Page 175: ...172 Multi VRF Indoor Unit Service Manual 3 Exploded View of GMV R112Zd NaB K GMV R125Zd NaB K...
Page 188: ...JF00301272...