You air conditioner is designed to install in standard double hung windows with 
opening widths of 23 to 36 inches (584 mm to 914 mm)(FIG.1). Lower sash must 
open sufficiently to allow a clear vertical opening of 14-1/2 inches (368mm).  
Side louvers and the rear of the AC must have clear air space to allow enough 
airflow through the condenser, for heat removal. The rear of the unit must be 
outdoors, not inside a building or garage.

23 to 36” (584 mm to 914mm)

14 ½” min

(368 mm) 

Offset

Exterior 
wall

Stool sill

Interior
wall

Note:

  

SAVE CARTON and these INSTALLATION INSTRUCTIONS for future reference. The carton 
is the best way to store unit during winter, or when not in use.  
Some assembly is required. Please read these instructions carefully.

TOOLS NEEDED:

 

1)  Phillips Screw Driver

2)  Drill (If pilot holes are needed)

Mounting Hardware

Qty.

6

3/4” Screw

Sash lock

1

CAUTION

1)  When handling unit. Be careful to avoid cuts from sharp metal edges and aluminum fins on front 

and rear coils.

!

Summary of Contents for GJC05BV-A6NMNE1A

Page 1: ...de Beloeil Quebec Canada Made in China OWNER S MANUAL WINDOW TYPE AIR CONDITIONER MODEL GJC05BV A6NMNE1A Thank you for choosing our product Please read this owner s manual carefully before operation...

Page 2: ...e chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all Contact the authorized service technician for repair or maintenance of...

Page 3: ...amage your health Do not modify power cord length or share the outlet with other appliances Do not operate with wet hands or in damp environment Always install circuit breaker and a dedicated power ci...

Page 4: ...se the window in storm or hurricane Always insert the filters securely Clean the filter once every two weeks Ensure that the installation bracket of the outdoor appliance is not damages due to prolong...

Page 5: ...s not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle 4 Ensure the receptacle is accessible after the unit installat...

Page 6: ...provided many important safety mes sages in this manual and on your appliance Always read and obey all safety mes sages ELECTRICAL REQUIREMENTS The electrical ratings for your air conditioner are lis...

Page 7: ...d with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and powe...

Page 8: ...The rear of the unit must be outdoors not inside a building or garage 23 to 36 584 mm to 914mm 14 min 368 mm Offset Exterior wall Stool sill Interior wall Note SAVE CARTON and these INSTALLATION INST...

Page 9: ...bottom of the packaging material as shown in Fig A 3 Tear off the paster at back side of sponge and then align it at the bottom edge of upper guide rail to stick the sponge at the bottom of upper guid...

Page 10: ...face 2 Locate the accordion panels in the box 3 Gently pull the free end of the accordion panel See FIG 2 Do this for both panels 4 Slide the free end of the accordion panel into the side panel of the...

Page 11: ...of the window WEATHER PROOF TYPE WINDOW The height of window frame is higher than windowsill for some weather proof type window which will affect the installation of air conditioner In this case befor...

Page 12: ...e window Insert the foam between the window sashes to prevent air and objects from getting into the room See FIG 12 Placing the Unit Inside a Window 1 Turn the air conditioner off and disconnect the p...

Page 13: ...least 3 minutes before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker 2 Do not try to operate your air conditioner in the cooling mode when out...

Page 14: ...rature Rotate the thermostat selector clockwise for higher cool settings Higher cool settings will provide lower room temperature Rotate the thermostat selector counter clockwise for lower cool settin...

Page 15: ...ith a mild detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency 4 Replace air filter by sliding filte...

Page 16: ...inutes after turning the unit off before trying to restart the air conditoner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip Reset butto...

Page 17: ...The outside temperature is below 60 F 16 C Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 60 F 16 C The temperature of the room you are trying to...

Page 18: ...uring the warranty period if this Air Conditioner fails under normal use GREE will at its option either repair the unit or replace it free of charge within a reasonable period of time after the Air Co...