U-Match Series Service Manual
43
Figure 3-1-14 Figure 3-1-15
(11) There is adhesive on one side of the insulation so that after removing the protective paper over
it the insulation can be directly attached to the drain hose.
(12) Considerations for the unit with the condensate pump:
1) For the unit with the condensate pump, only one drain port at the side close to the electric
box is prepared and only through it the drain hose can be connected.
2) See table 3 for the size of the drain port of the unit with the condensate pump, which is
different from that of the unit without the condensate pump.
3) For the unit with the condensate pump, two drain ports at the bottom are defaulted to be
factory plugged with drain caps. After the installation of the drain hose, these two drain ports
also need to be insulated properly with the same way aforementioned.
4) The drain hose for the unit with the condensate pump should be arranged as shown in the
figure below.
Figure 3-1-16
a) The vertical height of the drain hose should be 75mm or less so that it is unnecessary for
the drain port to withstand additional force.
Figure 3-1-17
b) When multiple drain hoses are used, their installation should be performed as shown in the
figure below.
Summary of Contents for GFH60K3HI
Page 1: ...T1 R410A 50Hz GC201510 U MATCHAIR CONDITIONERS SERVICE MANUAL...
Page 4: ...U Match Series Service Manual 1 PRODUCT...
Page 16: ...U Match Series Service Manual 13 4 PIPING DIAGRAM...
Page 17: ...U Match Series Service Manual 14 CONTROL...
Page 18: ...U Match Series Service Manual 15 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation...
Page 19: ...U Match Series Service Manual 16 1 2 Heating Operation...
Page 38: ...U Match Series Service Manual 35 INSTALLATION...
Page 72: ...U Match Series Service Manual 69 MAINTENANCE...
Page 77: ...U Match Series Service Manual 74 E4 Discharge Protection E6 Communication Malfunction...
Page 87: ...U Match Series Service Manual 84 Model GKH60K3HI...
Page 102: ...U Match Series Service Manual 99 Model GUHN30NK3HO Exploded Views and spare parts list...
Page 104: ...U Match Series Service Manual 101 Model GUHN36NM3HO Exploded Views and spare parts list...
Page 106: ...U Match Series Service Manual 103 Model GUHN42NM3HO Exploded Views and spare parts list...
Page 108: ...U Match Series Service Manual 105 Model GUHN48NM3HO Exploded Views and spare parts list...
Page 110: ...U Match Series Service Manual 107 Model GUHN60NM3HO Exploded Views and spare parts list...
Page 118: ...U Match Series Service Manual 115 Model GFH48K3H1I exploded view and spare parts list...
Page 120: ...U Match Series Service Manual 117 Model GFH60K3H1I exploded view and spare parts list...
Page 122: ...U Match Series Service Manual 119 Model GFH18K3HI exploded view and spare parts list...
Page 124: ...U Match Series Service Manual 121 Model GFH24K3HI GFH30K3HI exploded view and spare parts list...
Page 126: ...U Match Series Service Manual 123 Model GFH36K3HI GFH42K3HI exploded view and spare parts list...
Page 128: ...U Match Series Service Manual 125 Model GFH48K3HI exploded view and spare parts list...
Page 130: ...U Match Series Service Manual 127 Model GFH60K3HI exploded view and spare parts list...
Page 134: ...U Match Series Service Manual 131 Model GKH24K3HI GKH30K3HI exploded view and spare parts list...
Page 139: ...U Match Series Service Manual 136 Model GKH60K3HI exploded view and spare parts list...
Page 141: ...JF00302749...