background image

- 1 -

Precautions

Warning

Working temperature range

※ 

Operating Temperature Range

Indoor side DB/WB(°C)

Maximum cooling

32/23

43/-

Maximum heating

27/-

24/18

Outdoor side DB/WB(°C)

The operating temperature range (outdoor temperature) for cooling only unit is 

18°C~ 43°C; for heat pump unit is -7°C~ 43°C.

electric shock.

Please contact dealer when you need to repair air conditioner.

injury or damage.

sensory or mental capabilities, or lack of experience and knowledge, unless they

have been given supervision or instruction.

● Do disconnect power supply when clea

ning air conditioner. Otherwise, it may cause

● Do not repair air conditioner by yourself

. It may cause electric shock or damage.

● Maintenance must be performed by qualified professionals.Othe

rwise, it may cause

● The appliance is not to be used by persons (including childre

n) with reduced physical,

● Children being supervised not to play w

ith the appliance.

Please install the devices for short-circuit protection and electrical leakage protection

According to the local safety regulations, u

se qualified power supply circuit and circuit 

when installing the air conditioner.

break.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.
The air conditioner should be installed in accordance with national wiring regulation.

Air Conditioner should be properly grounded. Incorrect grounding may cause electric 

shock.

hazard.

broken.

injury or damage.

personal injury.

● Do not connect air conditioner to multi-purpose socket.Otherw

● This appliance can be used by children aged from 8 years and 

above and persons

ise, it may cause fire 

● Do install the air switch. If not, it may cause malfunction.

● Do not spill water on the remote controller’otherwise the rem

ote controller may be

● Do not spray water on air conditioner. It may cause electric 

shock or malfunction.

● Do not extend fingers or objects into air inlet or air outlet

. It may cause personal

● Do not step on air conditioner, or put heavy objects. It may 

cause damage or

● Do not block air outlet or air inlet. It maycause malfunction

.

with reduced physical, sensory or mental capabilities or lack of experience and

knowledge if they have been given supervision or instruction concerning use of the

appliance in a safe way and understand the hazards involved.

Summary of Contents for G1807VM

Page 1: ...Window type Air Conditioner Models G1807VR G1812VR G1807VM G1812VM G1824VM G1809VR G1818VR G1809VM G1818VM...

Page 2: ...nance 3 3 4 7 2 Precautions 1 After service 20 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowl...

Page 3: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Page 4: ...ply circuit and circuit when installing the air conditioner break Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision The air con...

Page 5: ...pring Summer Autumn Wind direction Winter Cooling in summer In hot summer Air conditioner can cool down theroom air by transferring heat out Without reducing the room temp air conditionercan dehumidif...

Page 6: ...water af ter running for so much time But this is normal Water pipe The electric components will be damaged when the voltage is too high If the voltage is too low the compressor will vibrate violently...

Page 7: ...us gas or other special areas please contact the seller before use Avoid a place where is possible for inflammable gas to leak out Avoid other heat sources or direct sun light Avoid a place where is e...

Page 8: ...he enlargement of noise or vibration 3 Fill up sews in the cabinet with sponge or foam Installation assistance Use iron support The installation hole should be strong enough to support the air conditi...

Page 9: ...the drain pan to the corner of the cabinet with 2 screws 4 Connect the drain hose to the outlet on the drain pan bottom 5 Slide the chassis into its original place in the cabinet Drain water for one s...

Page 10: ...rcuit there must be electricity leakage protection switch and leakage current is less than 30mA Connecting method between air conditioners and power cord and interconnecting method of each individual...

Page 11: ...r inlet louver Front grille Air filter behind the front intake grille Power cord Front intake grille Air filter behind the front intake grille Front intake grille Remote control panel Vertical airflow...

Page 12: ...ature is not as desired after a reasonable period turn the thermostat When the thermostat control know is set to 10moisture may freeze onto evaporator fins and the thermostat control knob counter cloc...

Page 13: ...N OFF button MODE button button FAN button SWING button SLEEP button TIMER button Timer on Timer off Sending signal swing operation sleep operation lock set speed Set time Set temperature heat operati...

Page 14: ...button to adjust fan speed When selecting dry mode air conditioner will operate at low fan speed under dry mode In dry mode fan speed can t be adjusted When selecting fan mode air conditioner will op...

Page 15: ...ton to set Timer Off T OFF and H icon will be blinking Within 5s press or button to adjust the time for Timer Off Pressing or button once will increase or decrease the time by 0 5h Hold or button for...

Page 16: ...al Child lock function Temperature display switchover function Under OFF status press button and MODE button simultaneously can switch between C and F Operation guide 1 After putting through the power...

Page 17: ...Make sure positions for pole and pole are correct 3 Reinstall batteries box cover The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles bet...

Page 18: ...ts and Press the keypad to decrease the selected time in 1 hour decrements The time seting range is from 0 24 hours 4 Press the keypad to increase the set operating temperature of the unit and Press t...

Page 19: ...room Air can t be discharged to the di rection of air in Make sure that the doors and win dows are tightly closed Avoid open ing doors and windows as much as possible to keep air conditioning in the...

Page 20: ...Do not pull out the power cord Damage to the cord may result in serious electric shocks s plastic parts will melt if exposed to excessive heat Avoid exposing the body directly to a continuous unidirec...

Page 21: ...nlet and outlet of the unit are blocked or not Let the filter dry thoroughly before reinstalling it If necessary please ask the professional personnel to clean it 2 Vacuum the filter on the dusty side...

Page 22: ...odor because the inlet air may be mixed with the smell of furniture and smoke For a noise that sounds like water flowing This is the sound of freon flowing inside the air con ditioner unit For a nois...

Page 23: ...air conditioner Electrical lines are much hot or lines cover breaks Other strange situations Immediately stop all operations and plug out please contact your dealerin the following situations After s...

Page 24: ...66129927469...

Reviews: