background image

8

INSTALLATION INSTRUCTIONS

To install the 

Upper Guide Rail

, peel off the 

back side of the 

Top Mounting Rail Seal 

Strip

 and align  

it on the bottom edge of the upper guide rail. 
Press the 

Top Mounting Rail Seal Strip

 onto 

the 

Guide Rail 

to fully seal. 

Use 

4 Type A Screws

 to attach the 

Upper Guide Rail

 onto 

the outer case of the air conditioner unit.
*Upper guide rail may be attached on some units

Before installing the 

Flexible Screens

, place one 

Flexible Screen Seal

 on the left side of the LEFT 

screen and right side of the RIGHT screen as shown.

To install the 

Flexible Screens

, ensure that the sides 

marked LEFT and RIGHT are installed into the left and 
right side of the unit. 

A) Hold Frame with one hand while extending 

Flexible 

Screen

 with other hand. Slide edge of Flexible Screen 

into track on side of unit. 

B) Slide the upper and lower ends of the 

Flexible 

Screen

 Frame into the 

Upper

 and 

Lower Guide Rails

.

Upper Guide Rail

Left

Left

Right

Right

Top 
Mounting 
Rail Seal 
Strip

Flexible Screen

Flexible Screen Seal

Upper Guide Rail

Frame

Frame

3

4

1

2

A

B

Lower Guide Rail

NOTICE:

 

This picture is for reference only.  Please refer to the actual product for the appearance.

Remove
backing
from seal
strip

 Note:

 For 

safety,  
all four screws 
must be 
SECURELY 
fastened.

Upper Guide Rail*

Summary of Contents for G17-6ESCWAC1

Page 1: ...erial numbers below for your records Model Serial Date Purchased Please read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please v...

Page 2: ...LLATION INSTRUCTIONS 5 10 OPERATING INSTRUCTIONS 11 14 CLEANING MAINTENANCE 15 16 BEFORE YOU CALL 17 19 WARRANTY 20 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please r...

Page 3: ...not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical parts This may cause failure of the machine or electric shock Do not p...

Page 4: ...er cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUS...

Page 5: ...ion of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or v...

Page 6: ...for the standard vertical double hung window If you need to install the air conditioner in a narrow window you may not need to use the Flexible Screen sub assembly Please refer to requirement of wind...

Page 7: ...il Window Unit Window Sill And Sash Seal With Adhesive 2 Flathead screwdriver Foam Top Gasket Without Adhesive Top Mounting Rail Seal Strip Parts List INSTALLATION INSTRUCTIONS Parts and Tools Needed...

Page 8: ...as shown To install the Flexible Screens ensure that the sides marked LEFT and RIGHT are installed into the left and right side of the unit A Hold Frame with one hand while extending Flexible Screen w...

Page 9: ...ssary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained 5 6 8 Window Sill Sash Seal With Adhesive Note T...

Page 10: ...re 10 length Locate the Foam Insulation from the packaging Cut the insulation into a rectangular shape to match the width as measured in figure 10 Remove adhesive from back of Foam Insulation Stick th...

Page 11: ...and evaporates unwanted moisture without extra cooling Sleep Mode Automatically increases the set temperature 2 after the first hour and another 2 after the second hour This feature limits compressor...

Page 12: ...increments by 0 5 hours OPERATING INSTRUCTIONS Function Control Display DESCRIPTION FUNCTION Auto Fan Mode In this mode fan speed will automatically adjust to provide optimum comfort with the set temp...

Page 13: ...e in COOL DRY and ENERGY SAVER mode to maintain the most comfortable temperature Timer Button Press this button to initiate AUTO ON AUTO OFF timer Press this button twice to cancel auto timer i Feel B...

Page 14: ...to the user s preference Adjust the air frame up or down to direct the air flow according to the user s preference OPERATING INSTRUCTIONS Air Flow Adjustment NOTICE This picture is for reference only...

Page 15: ...ot of dust in the operation environment then clean more frequently Do not touch the metal fins in the air conditioner when removing the filter To clean panel surface wipe with a soft dry cloth Check t...

Page 16: ...Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batterie...

Page 17: ...igerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If the below errors...

Page 18: ...Codes appear please call Customer Service IF THESE SOLUTIONS FAIL PLEASE CALL 1 866 658 0466 FOR GREE CUSTOMER SERVICE BEFORE YOU CALL MALFUNCTION CODE SOLUTION F1 Please contact Customer Service F2 F...

Page 19: ...t to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty air filter Remove filter s and clean Temperature is set too high Turn temperature setting down Air louv...

Page 20: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Page 21: ...21 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110516 68ECWAC...

Reviews: