background image

5

 CAUTION

When handling the unit be careful to avoid cuts from any sharp metal edges  

and the aluminum fins on the front / rear coils.

IMPORTANT

Save these instructions for future reference.

Product failure due to any improper installation is not covered under the One Year Limited Warranty.

IMPORTANT: 

You MUST use the parts provided for installation as well as proper installation 

procedures as described in this manual when installing this Portable Air Conditioner.

 WARNING

• 

Observe all electrical governing codes and ordinances.  

• 

Do not use damaged or non-standard power cords.  

• 

Use caution during installation and maintenance.

• 

Use proper operation to prevent electric shock, casualty and other accidents.

• 

Proper installation is the responsibility of the installer. If not installed properly the warranty is void.  

• 

All parts described must be used with no substitutions.

Selection of Installation Location

Installing the unit in the following places can be dangerous and may cause malfunction: 
1.  Areas with strong heat sources, vapors, flammable or explosive gas, sulfated gas or volatile objects 

spread in the air. 

2. Near high-frequency devices such as welding machines, medical equipment, etc.

INSTALLATION INSTRUCTIONS

 

Requirements for Electric Connection  

• 

Follow the Electric Safety Information when installing the unit.  

• 

According to your local safety regulations, use a qualified power circuit.  

• 

Do not plug into an outlet if it is loose or damaged. It may cause electric shock.  

• 

 Please make sure the power supply complies with the requirement of air conditioner. Unstable power 

supply or wrong wiring may lead to electric shock, hazard or malfunction. Note: Electricity requirements 

are 115V (60 Hz).  

• 

Do not connect to the power outlet before finishing installation.  

• 

Please make sure the outlet is always grounded effectively, otherwise it may cause electric shock.  

The grounding resistance should comply with national electric safety regulations.

Before You Begin

Summary of Contents for G16-10PACSH

Page 1: ...ease read the entire manual carefully to ensure proper operation of the product To find an electronic version of this manual please visit www greeproducts com Phone 1 866 658 0466 Email customerservic...

Page 2: ...picture is for reference only Please refer to the actual product for the appearance PAGE IMPORTANT SAFETY INSTRUCTIONS 3 4 INSTALLATION 5 16 OPERATING INSTRUCTIONS 17 20 CLEANING MAINTENANCE 21 24 BE...

Page 3: ...pulling on the power plug Grip plug firmly and unplug to remove Do not disassemble or modify the unit Do not operate with wet hands Do not clean with water that may run inside the units electrical par...

Page 4: ...ot be reset Please contact Customer Service If the power cord is damaged then it cannot be repaired It MUST be replaced with a new power cord Please contact Customer Service Power Cord with 3 Prong Gr...

Page 5: ...of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or vola...

Page 6: ...n reach of the power cord Where to Install the Unit Ensure there is no obstruction near the air inlet or air outlet This unit is for indoor use only This unit must be positioned so that the plug is ac...

Page 7: ...e Hook 6 Filter Cover 7 Air inlet 8 Exhaust Hose Connection 9 Exhaust Hose 10 Exhaust Nozzle 11 Remote Control Storage Pocket 12 Drainage Port 12 6 5 7 11 10 9 8 INSTALLATION INSTRUCTIONS Unit Overvie...

Page 8: ...Panel Rain Shield Protective Guard Spring Washer 4 Washer 4 Nut 4 Bolt 4 AAA Battery 2 Exhaust Hose Screw 14 Drainage Pipe Drain Connector 1 Rubber Plug Bracket Cord Hook 2 Pipe Hook 2 Foam Seal Exhau...

Page 9: ...om Cord Hook should face downward Cord Hook Screw 1 2 Wind the power cord around the Cord Hooks Note Do not plug this unit in until exhaust hose is properly installed INSTALLATION INSTRUCTIONS Cord Ho...

Page 10: ...Pipe Hook Put the Rubber Plug into the other side of th Drainage Pipe connect it with the Pipe Hook and then connect it with the Pipe Clip Drainage Pipe Installation 1 2 NOTE Use the continuous drain...

Page 11: ...ring Washers 2 Nuts in this order B Attach the Rain Shield on top of the Support with 2 Bolts 2 Washers 2 Spring Washers 2 Nuts in this order Spring Washers Nuts Support Bolts Washers Nuts Washers Bol...

Page 12: ...ooden Window Bracket A Cut Foam with Adhesive to length of window and attach to top of Window Panel B Close window sash securely against the Window Panel Foam with Adhesive 20 5 20 5 38 5 A B The Wind...

Page 13: ...ert Adjustment Panel C For windows with inner height over 38 5 98 cm up to 56 7 144 cm insert Adjustment Panel and Extension Panel A B C Extension panel Adjustment panel Adjustment panel Foam Adhesive...

Page 14: ...in windows less than 20 5 52 07 cm high Secure the Window Panel to the window sill with 2 Screws Inner height of the window 20 5 52 07 cm 38 5 98 cm Adjustment Panel was added secure the Window Panel...

Page 15: ...t Nozzle previously assembled in Window Panel Slide Exhaust Hose Connection into the grooves located on the back of the unit Exhaust Hose Connection Exhaust Hose Connection Exhaust Hose Exhaust Hose E...

Page 16: ...rt as possible and without bends INSTALLATION AND DISASSEMBLY Exhaust Hose Connection NOTICE This picture is for reference only Please refer to the actual product for the appearance INCORRECT CORRECT...

Page 17: ...Protection with Auto Restart Remembers all settings when power is interrupted As soon as power is restored the A C will operate in the mode temperature and settings prior to power loss Evaporative Ex...

Page 18: ...an Speed Button Changes the fan speed Choose between Low Med High Auto Note Cannot be used in DRY Mode Timer Button When the unit is OFF the timer can be set automatically to turn ON the unit Timer se...

Page 19: ...ss condensation This mode is not available in AUTO or FAN mode Press this button again to turn off X FAN mode Sleep Button Press this button to enter into sleep mode If unit operates in COOL Mode afte...

Page 20: ...ical Louver to the lowest or the highest in the COOL or DRY mode with the fan speed set to Low for an extended period of time Condensation may form on the louvers CAUTION Do not adjust the Horizontal...

Page 21: ...ilter s are clean and dry reinstall the filter s The filters s should be cleaned once every three weeks If there is a lot of dust in the operation environment clean more frequently Do not use a hair d...

Page 22: ...t horizontal Take the Drainage Pipe from the Pipe Clip and pull out the Rubber Plug in the Drainage Pipe to discharge the water After discharging the water replace the Rubber Plug in the Drainage Pipe...

Page 23: ...rden hose not included ATTENTION When using continuous drainage option from the middle hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed dow...

Page 24: ...Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batterie...

Page 25: ...ds when the refrigerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If t...

Page 26: ...dels with touch pad controls set the unit at High FAN mode or High COOL mode and adjust the thermostat to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty ai...

Page 27: ...ing 2 System is blocked 1 Turn unit off pull out power plug Wait 30 minutes 2 Plug unit in and turn on 3 If code still appears please contact Customer Service H3 Overload protection for compressor 1 C...

Page 28: ...eplacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing removing installing...

Page 29: ...29 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M110316 8K10KPACS US...