background image

SPECIFICATIONS 

 
Model No. :

 GBI-34, GBI-41 

Power: 

120V/60Hz AC, 1500W 

Dimensions

 

 
INSERT: 

D1

H3

W3

W1

W2

H1

H2

 

 

units

inch (mm)

 

Model 

Over Size 

Flame View   

Others 

W1 

H1 

D1 

W2 

H2 

W3 

W4 

H3 

GBI-34 

33.5 

(850)

 

26.3 

(668) 

11.4 

(289) 

31.5 

(800) 

18.9 

(481) 

31.6 

(803) 

24.5 

(622) 

25.4 

(646) 

GBI-41 

40.4 

(1025) 

31.4 

(798) 

11.4 

(289) 

38.4 

(975) 

24.1 

(611) 

38.5 

(978) 

31.5 

(800) 

30.6 

(776) 

 
 
FRONT: LF, ARF, FAF 
                                                                                                                                             

units

inch (mm)

 

INSERT

 

FRONT 

SIZE 

MODEL NO. 

MODEL 

LF 

ARF 

FAF 

DIMENSION 

 

 

 

34

” 

GBI-34 

33.9×29.8 

(860×755) 

GBI-34 + LF-34 

GBI-34 + ARF-34 

GBI-34 + FAF-34 

41

” 

GBI-41 

40.8×34.8 

(1035×885) 

GBI-41 + LF-41 

GBI-41 + ARF-41 

GBI-41 + FAF-41 

 
 

W4 

Summary of Contents for GBI-34

Page 1: ...fire electric shock or other personal injury WARNING Read and understand this entire owner s manual including all safety information BEFORE plugging in or using this product Failure to do so could result in fire electric shock serious personal injury or death SAVE THESE INSTRUCTIONS CAUTION Keep this owner s manual for future reference If you sell or give this product away make sure this manual ac...

Page 2: ...ALLATION For flush wall recessed installation using mantels such as SAV AR 41 an alcove should be constructed before fireplace installation with the outlet located in it During installation of a recessed unit you simply plug in the unit slide it back into place and put on the mantle to close off the opening For service simply slide the unit out and unplug Outlet Fireplace Insert GBI34 41REV E ECR ...

Page 3: ... FIRE Regularly inspect all air vents to make sure they are free from dust lint or other blockage Unplug the unit and clean with a vacuum ONLY DO NOT rinse or get wet WARNING For residential use only NOT for commercial use NEVER use this fireplace for other than its intended purpose Extreme caution is necessary when any heater is used by or near children and whenever the heater is left operating a...

Page 4: ...EVER overload the circuit If this heater trips the circuit breaker unplug all other appliances on the same circuit before the next use Avoid plugging other appliances into the same circuit as this heater Connect to properly grounded outlets only NEVER plug this heater into an outlet that is old cracked or has any loose wires or connections Plugging this heater into a faulty outlet could result in ...

Page 5: ...34 33 5 850 26 3 668 11 4 289 31 5 800 18 9 481 31 6 803 24 5 622 25 4 646 GBI 41 40 4 1025 31 4 798 11 4 289 38 4 975 24 1 611 38 5 978 31 5 800 30 6 776 FRONT LF ARF FAF units inch mm INSERT FRONT SIZE MODEL NO MODEL LF ARF FAF DIMENSION 34 GBI 34 33 9 29 8 860 755 GBI 34 LF 34 GBI 34 ARF 34 GBI 34 FAF 34 41 GBI 41 40 8 34 8 1035 885 GBI 41 LF 41 GBI 41 ARF 41 GBI 41 FAF 41 W4 ...

Page 6: ...ket 2pcs Airflow plate 1pc Fireplace insert 1pc Front Face 1pc INSTALLATION 1 LOCATING YOUR ELECTRIC FIREPLACE Note Your new electric fireplace may be installed virtually anywhere in your home However when choosing a location ensure that the general instructions are followed For best results install out of direct sunlight Power supply service must be either completed or placed within the electric ...

Page 7: ... 300 30 9 785 0 0 4 INSTALLATION a With front LF ARF FAF Insert Socket Socket Fixing bracket Screw ST4x8 1 1 Gently push the insert into the front of the mantel 1 2 Secure the insert to the mantel panel with 2 ST 4x16 screws OR If your cutout is larger than the firebox fixing brackets can be used to relocate screw holes above the firebox in Step 1 3 ...

Page 8: ... This appliance can be operated by both remote control and manual button Once the unit has been properly connected to a grounded electrical outlet turn on the main power switch located on the bottom and right hand side of the appliance A beep should be heard when the power is first applied CAUTION The unit s power cord must be connected to a properly grounded and protected 120V outlet Always use g...

Page 9: ...ect button the unit will cycle through each effect Heater button Press once turns 750W heater on Pilot lights illuminated Press again turns 1500W heater on Pilot lights illuminated Press third time turns heater off Pilot lights illuminated To Reset the Heater Your heater includes a protection system that shuts off the heater if it overheats for any reason 1 Turn unit to off 2 Unplug unit wait 5 mi...

Page 10: ...bs and fuses which have a limited lifespan If a problem should occur the nature of the problem together with the date of a purchase should be immediately reported to the retailer that the appliance was purchased from Proof of purchase will be required so the original receipt should be retained Warranty applies to the original owner only and is non transferrable BUTTON FUNCTION POWER Press once tur...

Page 11: ...nplug unit and clean blower Defective blower Blower replacement or repair necessary Odor coming from heater blower Normal operation Heater is burning off dust accumulated during manufacture or non use periods This should only be noticeable for a brief period after turning on Defective heater Heater may require replacement or repair Flame effect frozen or stuttering Defective flame motor Flame moto...

Reviews: