Application Rates
Condition
Solution
Individual shutoff slides in incorrect position
Position properly (open, closed, and two
intermediate positions
Mathematical error made during field
calibration
Recheck calculations
Catch sample not weighed accurately
Weigh sample again
Actual acreage less or more than calculated
Check area covered
Incorrect setting
Check control setting or meter calibration
Sprockets or chains slipping
Check tightness
Sprockets are incorrect size or ratio
Check sprocket assembly
Density of material differs from rate chart
Field calibrate
Binding of metering shaft
Check and clean bearings
Zero-Max turning in non-preferred direction
Since Zero-Max turns faster in non-pre-
ferred direction (marked by an arrow), com-
pensate and lower the setting by checking
application rate through calibration
Stripping of Sprocket Teeth
Condition
Solution
Binding of metering shaft
Check and clean bearings
Do Not
oil or grease the black bearing
Product not Metering
Condition
Solution
Individual shutoff slides closed
Open to correct position
Tube is kinked
Check tube routing
Blockage at metering wheel
Check and clean
Material has bridged in hopper or mixing
chamber
Loosen and agitate
Tube end is blocked and material is blowing
back out of mixing chamber
Clear blockage. Check for tube kinking
Manifold opening is blocked
Check and clean manifold by removing
expansion plugs
Air pressure too low
Check blower,
increase rpm if gauge indicates
Summary of Contents for HT1100-40
Page 2: ...This Page Intentionally Left Blank ...
Page 16: ...Page 16 OPERATION MANUAL Set Up Operation WIRING CONNECTIONS 6245DS GP S1 ...
Page 35: ...Page 35 OPERATION MANUAL THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 37: ...Page 37 OPERATION MANUAL THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...Great Plains Mfg Inc 1525 E North Street Salina Kansas 67401 USA www greatplainsmfg com ...