3N-40P
Hydraulic Drive Operation
51
2019-03-14
196-538M
38. When the sample run-time has expired, the motor
stops, the indicator above the ENGAGE button goes
out, and the console displays the estimated sample
generated (based on actual motor performance,
which may vary slightly from calculations).
The number display is normally very close to the
sample size entered at step 30.
39. Exit the tractor cab and obtain the net weight of the
samples. If multiple rows were sampled, divide the
total seed weight by the number of row sampled.
40. Enter the actual amount metered per row using the
/
arrow buttons.
Press FUNCTION button to advance to next window.
Figure 65
Cal. Mode Normal Completion
28261
Example:
Three 4 oz. containers were used at 3 rows.
ContainerWeight
= (4 x 3 /16), or
0.75 lbs.
Weight of containers and metered seed was:
GrossWeight
= 3.66 lbs.
SampleWeight
= 3.66 - 0.75, or
2.91 lbs.
AmountedCollected
= 2.91 / 3, or
0.97 lbs.
SampleWeight
GrossWeight ContainerWeight
–
=
AmountCollected
SampleWeight
RowsSampled
----------------------------------
=
Figure 66
Cal. Mode Enter Seed Count
28262