3N-40P
Hydraulic Drive Operation
59
2019-03-14
196-538M
Ag Leader PF3000
Settings for Ag Leader PF3000 Monitors used with
Precision Population Controller
QUICK REFERENCE
GUIDE.
1. Create a .tgt recipe file in SMS 2.0 or FarmWorks
Site Pro, or other software that will create a .tgt file,
and copy it to an SRAM or Flash card that is
compatible with the PF 3000.
PF3000 Settings:
2. Press SETUP key.
Press SWATH key.
Set swath to that of your Great Plains Precision
Seeding System.
3. Press SETUP key.
Press VEHICLE key.
Set Primary speed sensor to GPS.
4. Press SETUP key.
Press CARD key.
Set the following:
•
Log Device: None.
5. Press SETUP key.
Press APP RATE key.
Set the following:
•
Application Control: On
•
Look Ahead: On
•
Current target file: press Edit to view the files you
have on the card; select the one you wish to use.
6. Press SETUP key.
Press CONTROLLER key.
Select controller as Rawson Accu-Rate.
Press EDIT SETTINGS. Set the following:
•
Number of pulses/10 revolutions: 500
•
Nominal rate: Divide the highest rate on your
recipe by 1.6. This is your Nominal rate. If your
highest rate is 32, your nominal rate is 20.
•
Percent rate change: set to 4%
•
Area count: Set to Standard
•
Stop height: Set to 8
•
Act. rate recording method: Set to Sensor
•
Controller time delay: Set to 4 sec.
•
Application offset from GPS:
Distance from GPS to seed tubes.
•
Serial Port: Port 3
7. Press SETUP key.
Press PRODUCT key.
Select product and press EDIT SETTINGS.
Set the following:
•
Controller Device: Rawson Accu-RateCal.
number for act. rate: set to 0
•
Actual Rate Scale Factor: Set to 1.000
•
Target Rate Units: Set to Seeds
•
Actual Rate Units: Set to Seeds
•
Target conversion Number: 1
•
Target Rate increment: Determines the
increment value by which you can change the
manual target rate with each press of the arrow
keys.
8. Press FIELD key.
Set Field.
Set Product (press button to right of product)
Figure 86: PF3000:
Serial Connection to Controller
28322
1