@SWB7 USER MANUAL
9
Baud rate:
B 1200
: Baud rate 1200
B 2400
: Baud rate 2400
B 4800
: Baud rate 4800
B 9600
: Baud rate 9600
B19200
: Baud rate 19200
B38400
: Baud rate 38400
Remarks:
Format 1 o
utput examples :
Format 2 o
utput examples :
Format 3 o
utput examples :
Format 4 o
utput examples :
Format 3 and format 4 if you want to print the total weight, press the key
twice, and the accumulative weight will be removed.
Communication Protocol:
UART signal of EIA-RS232 C
Format:
1. Baud rate: 9600
2. Data bits : 8 bits
3. Parity bits: None
4. Stop bits : 1 bit
Format 1 (232 1
– 3):
HEAD1 (2 BYTES) HEAD2 (2 BYTES)
OL
– Overload
ST
– Stable
NT
– Net weight
US
– Unstable
GS
– Gross weight
Fixed 18 BYTES ASCII (kg g t lb)
ST,GS,+ 1.000lb
+ 1.000lb
S/N WT/lb
---------------
0001 2.205
0002 2.205
---------------
0002 4.410
TICKET NO.0001
G 3.000lb
T 1.000lb
N 2.000lb
TOTAL NUMBER
OF TICKETS 0001
TOTAL
NET 2.000