Important Safety Information 

 

READ  ALL  INSTRUCTIONS  BEFORE  USING  SCALES  TO  ENSURE  MAXIMUM 
SAFETY, BEST PERFORMANCE, AND TO GAIN KNOWLEDGE OF OUR SCALE, 
IT IS ESSENTIAL THAT YOU OR ANY OTHER OPERATOR OF THE SCALE READ 
AND  UNDERSTAND  THE  CONTENTS  OF  THIS  MANUAL  BEFORE  OPERATING 
THE DEVICE. 

 

When using an electrical device, basic precautions should  always be followed, 

including the following: 
 

1.  Please use only the original power cord or DC adapter supplied with the scale.

  
Other cords or adapters may damage the scale.  

2.  DC adaptor is used to charge the battery, and scale can operate without DC 

adaptor. 

3.  Avoid using long power extension cords 

– this may cause interference 

4.  Do not use on surfaces or in areas where vibration, air movement or 

temperature change. 
Do not place in direct sunlight or near air conditioning vents. 

5.  Avoid high humidity (greater than 80%) that might cause condensation, and 

keep away from direct contact with water and other corrosive chemicals.  

6.  Static may influence the weighing result. To reduce the static, wipe the pan and

 scale with anti

static wipes. 

7. 

Don’t impact or drop heavy objects on the scale – this may affect accuracy, or 
cause damage. Do not stack material on the scale when it is not in use.   

8.  Battery should be removed if the scale is not used for a long period of time.  

Battery should be recharged every 3 months. 

9.  Place items to be weighed as close to center of the pan as possible 
10. Only use fingers to operate the keypad. Do not press with hard or sharp 

objects. 
 
 
 

 

Summary of Contents for SWB7

Page 1: ...WEIGHING SCALE user manual Please read this manual carefully before operation Important safety info Warranty Model SWB7 GRAVITY MEASUREMENT INC...

Page 2: ...this may cause interference 4 Do not use on surfaces or in areas where vibration air movement or temperature change Do not place in direct sunlight or near air conditioning vents 5 Avoid high humidity...

Page 3: ...er should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims...

Page 4: ...ing use bench for use on four only adjust foot adjust the balance using the bubble level 2 Use independent source avoid other electrical disturbance 3 Don t put any object on the platter when turn on...

Page 5: ...in setup mode 1 To subtract the container s weight 2 To move one space to the right or upward in setup mode 1 To view gross or net weight when the balance is on tare status All other keys will be disa...

Page 6: ...ove to next parameter press the key 4 To exit and return to normal weighing press the key UF 2 High Low limits setting 1 Press the key to enter 2 The display will show 00 000L set low limit 3 Use the...

Page 7: ...off after 1 minute of non use This time can be set up to 99 minutes 1 Press the key to access to auto power configuration 2 Use the keys and to move cursor and press the to select number 3 Press the k...

Page 8: ...64 times within the hold range 5 Press the key to confirm UF 6 RS 232 Output 1 Press the key to enter 2 The display will show 232 1 3 Press the key to select the modes 4 Press the key to confirm and w...

Page 9: ...rint the total weight press the key twice and the accumulative weight will be removed Communication Protocol UART signal of EIA RS232 C Format 1 Baud rate 9600 2 Data bits 8 bits 3 Parity bits None 4...

Page 10: ...able net weight S T N T 0 0 0 8 7 6 k g 0D 0A 2 Example 1 568 lb unstable gross weight U S G S 0 0 1 5 6 8 l b 0D 0A 3 Example 20 5 40 lb oz unstable gross weight S T G S 1 0 0 5 4 0 l b o z 0D 0A 4 E...

Page 11: ...peed setting Modes spEED1 Standard speed spEED2 High speed spEED3 Low speed 1 Press the key to enter 2 Press the key to select the desired mode 3 Press the key to confirm UF 8 Zero tracking Modes Zp 0...

Page 12: ...libration weight 00 6 000 4 Use the keys and to select the digit press key to input the weight value 5 Put the calibration weight on the platter and press the key to calibrate The scale will return to...

Page 13: ...Keep pressing the ON T key not release while turning on the indicator After self checking finishes it displays P 0000 Input the password P 0020 and then press M to enter the parameter setting mode Pre...

Page 14: ...ion using unit lb 110002 ABCDEF A 0 disabled 1 Kg 2 Ton 3 g B 0 disabled 1 lb 2 lb oz C 0 disabled 1 TW Kg 2 HK kg 3 VISS D 0 disabled 1 PCS off 2 PCS ON E 0 disabled 1 Multi interval 2 Multi range F...

Page 15: ...D 1 animal weighing LF6 Certification Status nonE is for non certified scales and oiML is for NTEP United States or OMIL Europe LF7 Gravity Adjustment The same operation as UF 9 Gravity Adjusting LF8...

Page 16: ...SWB7 USER MANUAL 16 Officially Distributed By GRAVITY MEASUREMENT INC...