Gravity Measurement SWB7 User Manual Download Page 15

@SWB7  USER  MANUAL 

 

15 

*It was blocked when UF-5 set of HOLD 1 
*1=15Hz    2=30Hz    3=7.5Hz 
 

L F 5

      Zero Tracking 

The same operation as 

U F   8

 Zero Track 

*It was blocked when 

U F - 5

 set of HOLD 1(animal weighing) 

 
 

L F 6

      Certification Status 

n o n E

  is  for  non-certified  scales,  and 

o i M L

  is  for  NTEP  (United  States)  or  OMIL 

(Europe) 

 
L F 7

      Gravity Adjustment 

 
The same operation as 

U F   9

 Gravity Adjusting 

 

L F 8

      Zero 

Press

M+

key to set the initial zero function 

S E t Z   Y

 

y

 

Reset of the zero point each time when the scale switches on 

n

 

Disable resetting zero when switching on the scale 

 

 

 

Summary of Contents for SWB7

Page 1: ...WEIGHING SCALE user manual Please read this manual carefully before operation Important safety info Warranty Model SWB7 GRAVITY MEASUREMENT INC...

Page 2: ...this may cause interference 4 Do not use on surfaces or in areas where vibration air movement or temperature change Do not place in direct sunlight or near air conditioning vents 5 Avoid high humidity...

Page 3: ...er should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims...

Page 4: ...ing use bench for use on four only adjust foot adjust the balance using the bubble level 2 Use independent source avoid other electrical disturbance 3 Don t put any object on the platter when turn on...

Page 5: ...in setup mode 1 To subtract the container s weight 2 To move one space to the right or upward in setup mode 1 To view gross or net weight when the balance is on tare status All other keys will be disa...

Page 6: ...ove to next parameter press the key 4 To exit and return to normal weighing press the key UF 2 High Low limits setting 1 Press the key to enter 2 The display will show 00 000L set low limit 3 Use the...

Page 7: ...off after 1 minute of non use This time can be set up to 99 minutes 1 Press the key to access to auto power configuration 2 Use the keys and to move cursor and press the to select number 3 Press the k...

Page 8: ...64 times within the hold range 5 Press the key to confirm UF 6 RS 232 Output 1 Press the key to enter 2 The display will show 232 1 3 Press the key to select the modes 4 Press the key to confirm and w...

Page 9: ...rint the total weight press the key twice and the accumulative weight will be removed Communication Protocol UART signal of EIA RS232 C Format 1 Baud rate 9600 2 Data bits 8 bits 3 Parity bits None 4...

Page 10: ...able net weight S T N T 0 0 0 8 7 6 k g 0D 0A 2 Example 1 568 lb unstable gross weight U S G S 0 0 1 5 6 8 l b 0D 0A 3 Example 20 5 40 lb oz unstable gross weight S T G S 1 0 0 5 4 0 l b o z 0D 0A 4 E...

Page 11: ...peed setting Modes spEED1 Standard speed spEED2 High speed spEED3 Low speed 1 Press the key to enter 2 Press the key to select the desired mode 3 Press the key to confirm UF 8 Zero tracking Modes Zp 0...

Page 12: ...libration weight 00 6 000 4 Use the keys and to select the digit press key to input the weight value 5 Put the calibration weight on the platter and press the key to calibrate The scale will return to...

Page 13: ...Keep pressing the ON T key not release while turning on the indicator After self checking finishes it displays P 0000 Input the password P 0020 and then press M to enter the parameter setting mode Pre...

Page 14: ...ion using unit lb 110002 ABCDEF A 0 disabled 1 Kg 2 Ton 3 g B 0 disabled 1 lb 2 lb oz C 0 disabled 1 TW Kg 2 HK kg 3 VISS D 0 disabled 1 PCS off 2 PCS ON E 0 disabled 1 Multi interval 2 Multi range F...

Page 15: ...D 1 animal weighing LF6 Certification Status nonE is for non certified scales and oiML is for NTEP United States or OMIL Europe LF7 Gravity Adjustment The same operation as UF 9 Gravity Adjusting LF8...

Page 16: ...SWB7 USER MANUAL 16 Officially Distributed By GRAVITY MEASUREMENT INC...

Reviews: