24
Cycle Mode Configuration for LiPo, Lilon, LiFe, NiCd, NiMH, Pb Battery
Tap the screen and activate the item as white color.
And you can input the data. The Charge/Discharge
Current cannot be configured at this screen. The
configured values at the Charge/Discharge Mode
shall be progressed. Tap the cycle mark long, and
then it will be moved to the next step.
1)3 steps for cycle operation
C > D --- Charge-Discharge (Discharge after charging)
D > C --- Discharge-Charge (Charge after discharging)
D:C > D --- Discharge: Charge-Discharge
(one time discharge: Discharge after charging)
(the first D step : one time progress)
2)Cycle ---- desired cycle counts (1~10 times)
3)C->D Delay -Delay time before Discharging after charging (1~30min)
4)D->C Delay --- Delay time before Charging after discharging (1~30min)
The Values of Charge/Discharge are the data configured from the Charge/Discharge
Mode. To revise the data, please move to the charge/discharge mode.
Cycle Mode Configuration after Menory setting for LiPo, Lilon, LiFe, NiCd, NiMH, Pb Battery
(1) Balancer port Test
After configuration, tap the battery
mark long and the balancer board
test will be performed. And then it
will be stand-by for start.
This screen will be presented
if the balancer is not connect-
ed. And the Cell count could not
be changed by manual. Tap the
screen and it will be stand-by for
start.
(It will not be presented in case
of NiCd and NiMH)